30
Lift does not move in downwar
ds dir
ection (left)
or upwar
ds dir
ection (right)
Code: “6”
Connect the molex testing link
The rail is on the rightside of the
stairs. The lift will not move up.
The voltage between M7-8 and
gr
ound is 3,5 V
Main boar
d P1 is faulty
The rail is on the leftside of the
stairs. The lift will not move up.
The voltage between M7-8 and
gr
ound is 3,5 V
Main boar
d P1 is faulty
The rail is on the right side of
the stairs.
The lift will not move up.
The voltage between M7-8 and
gr
ound is not 3,5V
Ther
e is an obstacle blocking the
upperside of the pack or
the upperside of the footr
est
Ther
e is a br
eak in the curr
ent in the
line: M7-8,U9-6,U9-5,M7-7
The footr
estswitch
S7 is faulty
The rail is on the left side of
the stairs.
The lift will not move down.
The voltage between M7-8 and
gr
ound is not 3,5 V
Ther
e is an obstacle blocking the
downside of the pack
or the downside of the footr
est
Ther
e is a br
eak in the curr
ent in
the line: M7-8,U9-1,U9-2, U9-6,U9-5
and M7-7
The fr
ont chassis edge switch
S11 or S12 is faulty
The footr
est switch S7 or S9
is faulty