Quick Reference Guide Handicare 2000
35
The hinge is operated but the lift won’
t move
Code “8” or “9”
Ther
e is br
eak in the curr
ent between
M23-1 and M23-2 or M23-3 and M23-4
The top endswitch of the folding hinge S33 is faulty
.
If the top limit switch is defective, after a short delay
,
the lift would be allowed to drive UP but the hinge would be
left in the position it is in.
The endswitch of the folding hinge S31,S32 is faulty
The lift will not move down, but can move up