Installation distance to walls and ceiling
550
16
00
min 23
00
Combustible roof
Air inlet Ø64
120
430
43
0
105
0
114
0
167
Hole in foot plate Ø120
Place the stove on the hearth plate and
check that the installation distances
given in the figures below are followed.
The minimum distance in front of the
stove opening to combustible parts of the
building or interior decoration must be at
least 1 m.
3
6
8
15
0
729
781
Combustible wall
26
7
100
415
400
300
100
3
00
200
100
690
Combustible wall
Permitted area for
combustible material
H34T
*To prevent discolouration of painted fire walls, we recommended the same side distance as to combustible walls.
26
8
5
0
629
64
0
Fire-retardant wall of
brick or concrete
21
7
5
0
50*
325*
Fire-retardant wall of
brick or concrete
When top connecting a steel
flue please refer to the relevant
manufacturer’s installation
instructions. Observe the safety
distances to combustible material
that steel flues require.