13
High exhaust temp. lamp
W98
Engine
:
lamp on
Caution
Remind the driver of high exhaust
temperature during regeneration, and pay
attention to safety.
Inhibit Regeneration Lamp
This light indicates that the regeneration state
of the engine is limited and the requested
regeneration cannot be performed at this time.
Caution
Work in an environment that is not suitable
for DPF regeneration. Turn on the
regeneration prohibition. After leaving, the
regeneration prohibition should be lifted in
time to turn off the regeneration prohibition
indicator so that active regeneration can
continue.
Warning
If active regeneration is always prohibited,
the exhaust filter will be blocked, exhaust is
blocked, and the forklift's performance will
deteriorate until the engine fault indicator is
activated .
EATS fault indicator lamp
To indicate that the engine EATS (Exhaust After
Treatment System) has failed or falls outside of
specified operating parameters.
At the same time, the engine fault light is on.
Regeneration Needed/Request Lamp
There are three
working states: driving
regeneration, parking regeneration, service
regeneration (after-sale program).
In the first case
,
the regeneration indicator
lights up permanently and is in the regeneration
working state. No manual intervention is required
at this time, and only the normal working state
needs to be maintained.
The regeneration reminder will automatically
go out, which also means that the particulate
matter processing is completed.
What the driver has to do is to reduce the
light load running time as much as possible in
order to increase the exhaust temperature and
shorten the regeneration time.
In the second case
,
prompt to stop and start
parking regeneration.
Parking regeneration meets the following
conditions:
①
The forklift is parked on a well ventilated flat
road.
②
Pull up the handbrake.
③
Release the accelerator pedal.
④
The reversing operation lever is kept in
neutral (N range).
⑤
Preheat the forklift until the water temperature
reaches 70
℃
.
A hazard warning sign is placed near the exhaust
port.
Turn on parking regeneration (see instrument
key operation instructions).
After the regeneration is complete, the lamp will
turn off automatically, and after 2-3 minutes the
engine returns to normal idle speed, you can
shut down the engine.
Caution
Parking regeneration: parking state, not
conducive to heat dissipation. Keep away
from flammable materials and keep a safe
distance from people.
Drivers should pay attention to protection,
do not leave the scene, and always pay
attention to the engine condition during
regeneration.
It is best not to stop in the middle, otherwise
it is easy to cause DPF failure.
Warning
In case of emergency, parking regeneration
must be prohibited, exit any one of the
parking regeneration conditions
②
③
④
.
W98
Engine
The indicator light flashes during driving. If
the parking regeneration is not performed in time,
it is easy to cause DPF jams and may damage