13
traction controller, auxiliary traction controller (reserved), oil pump controller, auxiliary oil pump controller
(reserved), and lithium-ion battery monitoring information. Press button 4 to return to the main interface.
(
4
)
Press button 4 on the main interface to enter the setting page. Press
button 1 and button 2 to switch between different sub-page options.
Press button 3 to enter the selected sub-page, and press button 4 again
to return to the main interface.
6
、
Advanced setting page
Entering the advanced setting page requires inputting a four-digit password
first. The password input method is as follows: Use button 1
to move the cursor to the digit to be modified, use button 2 to change the
value, after all four digits are entered press button 3 to confirm.
If the password is correct, the advanced settings interface can be entered.
(1). Parameter settings interface
The parameter settings interface has 6 pages in total. 3 pages for traction
controller parameter settings, with 13 setup items. Among them, auxiliary
traction 1, auxiliary traction 2,
auxiliary traction 3 are reserved items with no function. There are 3 pages
for oil pump controller parameter settings, with 12 setup items.
Among them, auxiliary oil pump 1, auxiliary oil pump 2, auxiliary oil pump 3
are reserved items with no function.