7
Gasoline engine / LPG engine: H1, H3
Engine fuel: Gasoline
Engine fuel: LPG
ECO: Low LPG capacity prompts
that it should be supplemented
soon.
The fault diagnosis tester is
connected with the indicator
light
Regen indicator light
There are three kinds of working mode: Driving
regen, parking regen, and service regen
(aftersales solution).
In the first case
, the regen indicator light turns
on normally and is in the regen working status.
At that time, manual intervention is not
required and normal operation can be
maintained. The light will automatically turn off
after the regen prompt, which also indicates
that the treatment of particulate matters is
completed.
The driver should reduce light running time as
much as possible to increase the exhaust
temperature and shorten the regen time.
In the second case
, it prompts that the parking
regen should be started.
Start parking regen (see operating instructions
for instrument keys)
after meeting
parking
regen conditions.
Parking regen conditions:
①
The forklift truck is parked on a
well
-
ventilated flat road.
②
Pull the hand brake.
③
Release the accelerator pedal.
④
Keep the direction lever in the
neutral position (gear N).
⑤
Warm up the forklift truck until
the water temperature reaches 70
℃
.
⑥
Install the hazard Warning sign
near the exhaust port.
Caution
Parking regen: The parking status is not
suitable for heat dissipation. Stay away from
inflammables and keep a safe distance from
people.
The driver should pay attention to safety,
should not leave the site, and should monitor
the engine conditions during regen.
The driver should not stop the engine during
regen as this is likely to cause a DPF fault.
Warning
In case of emergency, parking regen is
inhibited, and only one of conditions
②③④ to exit parking regen needs to be
met.
The regen indicator light turns on when driving
and the forklift truck can continue to be used
normally or can be driven to a safe position for
parking regen.
If the regen indicator light turns on when
driving and the engine fault indicator light
turns on as well, maintenance personnel or
aftersales staff for the plant area should be
contacted to check the engine fault code. Start
the parking regen after confirming that there is
no other fault.
Caution
If the two indicator lights turn on and there is
no parking regen within 2h, the DPF is likely to
be blocked, the parking regen will fail to start,
and DPF may be damaged, causing
maintenance expenses.
H7/ H8
diesel
engine
Flash
Fault code
SPN:5270 FMI:15
W97,
W98,
W99
Diesel
engine
Flash
Fault code
GASO
LINE
LPG
HDM
3000
Summary of Contents for XF Series