SPECIFICATIONS

Rated Capacity

a

- (scfm)

10

15

Inlet /Outlet Connections - (inches)

3

8

3

8

Dimensions

Height - (inches)

15.4

15.4

Length - (inches)

12.6

12.6

Width - (inches)

12.6

12.6

Power Supply - (V/Ph/Hz)

115/1/60

115/1/60

Refrigerant Compressor Rating - (hp)

1/8

1/7

Input Power - (kW)

0.21

0.24

Refrigerant Type

b

R-134a

R-134a

MINIMUM - MAXIMUM OPERATING CONDITIONS

Min.-Max. Inlet Air Pressure (compressed air at inlet to dryer)

30 - 250 psig

30 - 250 psig

Min.-Max. Inlet Air Temperature (compressed air at inlet to dryer)

40°F - 122°F

40°F - 122°F

Min.-Max. Ambient Temperature

40°F - 113°F

40°F - 113°F

a

Rating conditions are 100°F inlet temperature, 100 psig inlet pressure, 100% inlet relative humidity, 100°F ambient temperature @ 60Hz. Per CAGI ADF-100

b

Refer to dryer data plate for refrigerant charge.

ENGINEERING DATA

Figure 1

ELECTRICAL SCHEMATIC

Figure 2

AIR AND REFRIGERANT FLOW SCHEMATIC

(Model 15 only)

E

N
G

L

I

S

H

Summary of Contents for HPR Series

Page 1: ...ING 2 STORAGE 2 INSTALLATION 3 INSTRUMENTATION 4 CONDENSATE DRAIN VALVE 4 START UP OPERATION 4 SHUTDOWN 4 MAINTENANCE PARTS LIST 5 FIELD SERVICE GUIDE 6 SPECIFICATIONS 7 ELECTRICAL SCHEMATIC 7 FLOW SC...

Page 2: ...ns for the requirements for breathing quality air RECEIVING MOVING AND UNPACKING A RECEIVING This shipment has been thoroughly checked packed and inspected before leaving our plant It was received in...

Page 3: ...the replaceable filter element Outlet air temperature may be 10 to 30 degrees higher than inlet air temperature This is normal Consult your distributor if a lower outlet air temperature is required Pi...

Page 4: ...d The dryers are fully automatic and require no auxiliary controls 1 Connect inlet and outlet lines to the dryer Reference dryer indentations and instruction tag for appropriate inlet and outlet conne...

Page 5: ...assembly serious personal injury and valve damage may result 5 Remove screw and washer from front of the drain valve 6 Remove the power supply connector and gasket with the timer assembly if attached...

Page 6: ...Refrigerant compressor stopped HIGH PRESSURE DROP SYMPTOM Low outlet pressure POSSIBLE CAUSE Failure of drain trap Aftercooler malfunction Leak in refrigerant system Compressor overheated Compressor...

Page 7: ...ITIONS Min Max Inlet Air Pressure compressed air at inlet to dryer 30 250 psig 30 250 psig Min Max Inlet Air Temperature compressed air at inlet to dryer 40 F 122 F 40 F 122 F Min Max Ambient Temperat...

Page 8: ...d by the manufacturer Unauthorized service voids the warranty and any resulting charge or subsequent claim will not be paid Products repaired or replaced under warranty shall be warranted for the unex...

Reviews: