background image

11

Make the following settings:

Program 1

Program 1

Program 1

Program 1

Program 1

Irrig ctrl mode (S53): Sets time mode
Active Timetable (S31): sets a valid range for the current day
Set priority (S33): sets 1 priority sect/group 4
Start conditions (S34): sets Time condition Y
Set start time (S35): sets three start hours ex: xx: 00, xx: 03, xx: 06
Set program repeats (S36): sets 0
Pre/post Irrig. (S37): sets 5s
Set sectors (S38): sets 4s for valves 1, 5, 9, 13, 17, 21, 25, 29

Program 2

Program 2

Program 2

Program 2

Program 2

Active Timetable (S31): sets a valid range for the current day
Set priority (S33): sets 3 priority; sect/group 4
Start conditions (S34): sets External tank 02
Set program repeats (S36): sets 0
Pre/post Irrig. (S37): sets 1s
Set sectors (S38): sets 10s for valves 1, 2, 9, 10, 16, 17, 24, 25
Set fertilizers (S39): 20%, 40%, 60%, and 80%
PH control (S40): sets Ref = 7.0;  –0.6 ; +0.6; threshold 2
Cond control (S41): sets Ref = 7.0; -0.6; +0.6

Program 3

Program 3

Program 3

Program 3

Program 3

Irrig ctrl mode (S53): Sets time mode
Active Timetable (S31): sets a valid range for the current day
Set priority (S33): sets 1 priority
Start conditions (S34): sets External tank 03
Set start time (S35): sets three start hours ex: xx: 00, xx: 03, xx: 06
Set program repeats (S36): sets 3
Pre/post Irrig. (S37): sets 1s
Set sectors (S38): sets 5s for valves 1, 2, 3, 9, 10, 11, 16, 17, 18, 24, 25, 26
Set fertilizers (S39): 20%, 40%, 60%, and 80%
PH control (S40): sets Ref = 7.0;  –0.6 ; +0.6; threshold 2
Cond control (S41): sets Ref = 7.0; -0.6; +0.6

Summary of Contents for HI 8001

Page 1: ...1 Installation Manual for technical personnel only HI 8001 and HI 8002 Agricare Fertigation Controller www hannainst com ...

Page 2: ...de contact list at www hannainst com TABLE OF CONTENTS 1 CONTROLLER HARDWARE PRESENTATION 3 1 1 Electrical specifications 3 1 2 Inputs Outputs Description 4 2 CONTROLLER INSTALLATION 6 2 1 Installation types 6 2 2 Connections Wiring 7 2 3 Controller start up 10 2 4 Testing for the customer 10 3 APPENDIX 1 ELECTRICAL DIAGRAMS 14 All rights are reserved Reproduction in whole or in part is prohibited...

Page 3: ...i D s t u p n i l a t i g i d 6 1 D N G o t t c a t n o C n i p k a e r B P M E T p o t s d n o c t n u o c g i r r i 2 1 s e r p f i d 4 3 2 1 l e v e l t r e f l e v e l d i c a l e v e l g n i x i m 5 4 3 2 1 k n a t t x e t u p n I l a i r e S e l a m 9 B D 2 3 2 S R 0 0 8 4 0 0 4 2 0 0 2 1 s p b 0 0 6 9 2 3 2 S R s t u p t u O l a t i g i D y a l e R s t u p t u o 4 3 A 0 1 p m u p n i a m s ...

Page 4: ...tal Inputs 1 2 2 Digital Inputs 1 2 2 Digital Inputs 1 2 2 Digital Inputs On the main board near the analog inputs the controller has 16 digital inputs with optical separa tion They are available only when the IN24Vac input is supplied with 24Vdc min 150mA The sensors have to be of switch type and connected to the COM IN pins near the last digital input When between a digital input and the COM IN ...

Page 5: ...ted to the COM IN pin 1 2 5 P 1 2 5 P 1 2 5 P 1 2 5 P 1 2 5 Power inputs ower inputs ower inputs ower inputs ower inputs The controller works when the 220V 110V dc power supply is connected to the 220Vac input and an auxiliary 24Vdc min 150mA voltage is connected to the IN24Vac input This source doesn t supply internally the digital outputs and should be separated from the external 24Vac power sup...

Page 6: ...architecture can be simplified pH and EC sensor number external tank number and fertilizer tank number The controller is produced in four versions 8 16 24 and 32 sectors The architecture should be clarified before starting the installation It depends on pH sensor number EC sensor number fertilizer tank number filter number external tank number differential presostate number sectors number agitator...

Page 7: ... 24Vdc 150mA source should be used for this supply It supplies the digital inputs The transformer that is used for the valves could provide the voltage for these inputs but it needs a separate winding The IN 24Vac input can be connected to the same transformer but in this case here connections with COM IN pins have to be avoided 2 2 3 Digital input connections 2 2 3 Digital input connections 2 2 3...

Page 8: ... EC in inputwill stayunconnected The transmitters will be supplied from the Vs outputs The maximum consumption supported by the controller is around 250mA 12V This means that two Hanna transmitters can be supplied from the same output 2 pH channels and 2 EC channels and one transmitter for the EC in sensor The following type of sensors can be connected to the transmitters HI 1001 HI 1001 HI 1001 H...

Page 9: ...the filters This operation is done by the four valves that are commanded alternatively two by two like in the schematic The controller provides a mechanical contact that is switched ON OFF periodically and it can be used in the installation to control the external relay see in the appendix 2 2 6 Main pump connections 2 2 6 Main pump connections 2 2 6 Main pump connections 2 2 6 Main pump connectio...

Page 10: ...Controller State should be in the STOP state Go in the S50 OUTLETS MANUAL CTRL panel For each output device connected to the controller you can verify the correct functioning step by step Set and clear the desired output according to the table from APPENDIX 2 Instruction Instruction Instruction Instruction Instruction Manual Manual Manual Manual Manual Calibrate the controller See section 6 1 Sens...

Page 11: ... conditions S34 sets External tank 02 Set program repeats S36 sets 0 Pre post Irrig S37 sets 1s Set sectors S38 sets 10s for valves 1 2 9 10 16 17 24 25 Set fertilizers S39 20 40 60 and 80 PH control S40 sets Ref 7 0 0 6 0 6 threshold 2 Cond control S41 sets Ref 7 0 0 6 0 6 Program 3 Program 3 Program 3 Program 3 Program 3 Irrig ctrl mode S53 Sets time mode Active Timetable S31 sets a valid range ...

Page 12: ...time Program 3 with repetitions Allows verifying the start condition ext tank 03 set valves irrigation time and repetitions Program 4 liked by another program Allows verifying the start condition ext tank 04 set valves and the irrigation time Sets the Start conditions S34 link 2 Starts the program 2 ext tank 02 Allows verifying the link with program 2 Manual started Goes in S47 and starts manually...

Page 13: ...Service department and then send it with shipping costs prepaid When shipping any instrument make sure it is properly packed for complete protection RECOMMENDA RECOMMENDA RECOMMENDA RECOMMENDA RECOMMENDATIONS FOR USERS TIONS FOR USERS TIONS FOR USERS TIONS FOR USERS TIONS FOR USERS Before using this product make sure it is entirely suitable for your specific application and for the environment in ...

Page 14: ...E 4 VALVE 5 VALVE 6 VALVE 7 VALVE 8 PUMP AGITATORS COM OUT 1 220 Vac 220 Vac 200 mA FILTER 1 FILTER 2 pH FERT 1 FERT 2 FERT 3 FERT 4 COM OUT 2 4 A 4 A IN 24 Vac IN 24 Vac NC ALARM NO ALARM COM OUT AL EC 1 EC 2 EC IN UNUSED UNUSED SOLAR RAD Vs 12V Vs 12V Vs 12V Vs 12V COM IN COM IN RS 232 TEMP BREAK COND STOP IRIG COUNT DIF PRES 1 DIF PRES 2 FERT LEVEL 1 FERT LEVEL 2 FERT LEVEL 3 FERT LEVEL 4 ACID ...

Page 15: ...15 DIGITAL OUTPUT ...

Page 16: ...16 ISTL8001 06 19 ...

Reviews: