Page 1: ...HI 93530 HI 93530N HI 93531 HI 93531N HI 93531R HI 93532 HI 93532N HI 93532R w w w h a n n a i n s t c o m K Thermometers Instruction Manual ...

Page 2: ...wner Hanna Instruments Hanna Instruments reserves the right to modify the design construction and appearance of its products without advance notice Dear Customer Thank you for choosing a Hanna product Please read this instruction manual carefully before using the instrument This manual will provide you with the necessary information for correct use of the instrument as well as a more precise idea ...

Page 3: ... 0 to 250 0 F 1 F outside Accuracy 0 5 C 100 0 to 999 9 C 1 C outside 20 C 68 F 1 F 148 0 to 999 9 F 1 5 F outside excluding probe error Typical EMC 3 C 6 F Deviation with HI 766 K thermocouple probe Battery 3x1 5V AA IEC LR6 batteries approx 500 hours of continuous use BL off Auto off user selectable 60 min or disabled Environment 10 to 60 C 14 to 140 F RH 100 Dimensions 150 x 80 x 36 mm 5 9 x 3 ...

Page 4: ...emaining battery life indication low battery detection Waterproof casing Auto off capability Backlight feature HI 93531N only User calibration at 0 C HI 93531N only SPECIFICATIONS Range 200 0 to 999 9 C 1000 to 1371 C 328 0 to 999 9 F 1000 to 2500 F Resolution 0 1 C 149 9 to 999 9 C 0 2 C 200 0 to 150 0 C 1 C outside 0 1 F 24 9 to 999 9 F 0 2 F 249 9 to 25 0 F 0 3 F 328 0 to 250 0 F 1 F outside Ac...

Page 5: ...values displayed on the LCD Remaining battery life indication low battery detection Waterproof casing Auto off capability Backlight feature HI 93532N only User calibration at 0 C HI 93532N only SPECIFICATIONS Range 200 0 to 999 9 C 1000 to 1371 C 328 0 to 999 9 F 1000 to 2500 F Resolution 0 1 C 149 9 to 999 9 C 0 2 C 200 0 to 150 0 C 1 C outside 0 1 F 24 9 to 999 9 F 0 2 F 249 9 to 25 0 F 0 3 F 32...

Page 6: ...or Fahrenheit Extended range 200 to 1371 C or 328 to 2500 F Relative and average measurements HOLD function HI LO Max Min temperature values displayed on the LCD Remaining battery life indication low battery detection Waterproof casing Auto off capability Backlight feature User calibration at 0 C RS232 serial port communication SPECIFICATIONS Range 200 0 to 999 9 C 1000 to 1371 C 328 0 to 999 9 F ...

Page 7: ...d the meter will return to normal measurement mode OPERATIONAL GUIDE To switch the instrument ON press the ON OFF key The thermometer will carry out a self diagnostic test routine the LCD will show all segments for a few seconds or as long as ON OFF is held followed by the percentage indication of the remaining battery life The thermometer then enters normal measurement mode If a temperature probe...

Page 8: ...ture while the lower portion displays the current tem perature for the selected channel The average mode will calculate the average for a period of up to 24 hours If a different mode is selected for that channel the average will no longer calculate and the value will be lost At the end of the 24 hour period the AVG tag will blink to indicate that sampling has stopped and the displayed value is the...

Page 9: ...t only take place in a non hazardous area using 1 5V AA IEC LR6 alkaline batteries BATTERY REPLACEMENT SERIAL PORT COMMUNICATION HI 93531R HI 93532R only HI 93531R and HI 93532R feature an RS232 output for transfer ring measurement data once every second for HI 93531R and once every 2 seconds for HI 93532R to devices provided with RS232 input PC or printer The communication protocol has been desig...

Page 10: ... unacceptable interferences to radio and TV equipments requiring the operator to take all necessary steps to correct interferences Any variation intro duced by the user to the supplied equipment may degrade the instruments EMC performance To avoid electrical shock do not use these instruments when voltages at the measurement surface exceed 24 Vac or 60 Vdc To avoid damages or burns do not perform ...

Page 11: ...942 Japan Tel 03 3258 9565 Fax 03 3258 9567 Korea Tel 02 2278 5147 Fax 02 2264 1729 Malaysia Tel 603 5638 9940 Fax 603 5638 9829 Singapore Tel 6296 7118 Fax 6291 6906 SouthAfrica Tel 011 615 6076 Fax 011 615 8582 Taiwan Tel 886 2 2739 3014 Fax 886 2 2739 2983 Thailand Tel 66 2619 0708 Fax 66 2619 0061 United Kingdom Tel 01525 850 855 Fax 01525 853 668 USA Tel 401 765 7500 Fax 401 765 7575 For e ma...