Hannl Reinigungssysteme Beyenburgerstrasse 21 42899 Remscheid.

T492191/842 976 ; T492191/842 977 ; E-Mail info@vinylcare.de

Summary of Contents for Aragon ELB

Page 1: ...Manual Hannl Reinigungssysteme Beyenburgerstrasse 21 42899 Remscheid Telefon 492191 842 976 Telefax 492191 842 977 E Mail info vinylcare de ...

Page 2: ... that you understood everything before installing and using the device This manual will provide you with technical guidance that ensures cleaning and care of your records trouble free use of your device and your safety We wish you a lot of enjoyment with your new record cleaner With best regards Your Hannl Team Hannl Reinigungssysteme Beyenburgerstrasse 21 42899 Remscheid Telefon 492191 842 976 Te...

Page 3: ...on to scrub a plate with a double brush head or a round brush for a longer period of time Due to the reduced rotation speed the detergent stays on the plate and won t be pushed off the plate by centrifugal force The automatic change of rotation direction allows cleaning the plate without having to stand The plate will be cleaned until you cancel the cleaning and vacuum the loosened dirt Included 1...

Page 4: ...he plate off softly and gently In the PLATEPosition you ve got the option to scrub a plate with a double brush head or a round brush for a longer period of time Due to the reduced rotation speed the detergent stays on the plate and won t be pushed off the plate by centrifugal force The automatic change of rotation direction allows cleaning the plate without having to stand The plate will be cleane...

Page 5: ... advantage that you don t must resign on your machine and you can use your machine If you want to update you become a new CPU from us and send back the old one A manual to change the CPU is included With the new 24V DC unit we have become the Limited Autom 24V DC much more quiet The Limited Autom 24V DC can bought in a based version without roundbrush for an cheap price With extension sets how a r...

Page 6: ...the direction of the plate in vacuum You can use this feature if you push the pump button in program VACUUM In the program VACUUM the machine changes the direction of the plate after 1 rounds In the program PLATE the machine changes the direction of the plate after 5 rounds For questions and problems we are very glad to help you please contact us under hannl hannl systems de ...

Page 7: ...and 5 Top view incl brushes and suction arm 5 1Suction arm 5 2 Double brush arm 5 3 Round brush 5 4 Tank 5 5 Weight 5 6 Turntable 6 Emptying used up cleaning liquid 7 Round brush 7 1 Installation of round brush 7 2 Startup of round brush 7 3 Application of cleaning fluid 7 4 Cleaning procedure 7 5 Maintenance and care 7 6 Adjustment of brushing roller 7 6 1 Scope of delivery of fixing tools 7 6 2 ...

Page 8: ...iginal washing liquid may be used when cleaning the records 9 If the unit emits an abnormal odor or smoke turn it off immediately and disconnect the power cable 10 You must not wear loose garments that can get trapped in the turntable 11 The device may only be used for the purpose of record cleaning 12 The device must not be left unattended while it is being operated 13 The device must not be used...

Page 9: ...r RB 1 microfibre cloth Tool for round brush Important note Please do not through away the original packaging You will need it to protect your cleaning maching from possible damages during transportation movings repairs Please do not hesitate to contact us if you have further questions about how to use the cleaning device 3 Installation Please note that this cleaning device makes use of liquids wh...

Page 10: ... the cleaning procedure set the PROGRAMME SELECTION SWITCH to the STOP Position After having used your device the installed fan might conduct damp air away up to 10 minutes Then aprox 10 minutes later your device will automatically shut down and go into standby mode The programme selection switch allows you to select between LEFT LIQUID RIGHT VACUUM AUTO R Hannl Reinigungssysteme Beyenburgerstrass...

Page 11: ...manually and apply the cleaning liquid via the brush you will have to choose between LEFT and RIGHT and then switch to LIQUID 4 5 VACUUM With the function VACUUM the suction equipment will be activated to take off the cleaning liquid without expenditure after finishing the cleaning process Please note that the clamp on the outlet hose is closed and the suction arm properly connected before choosin...

Page 12: ... turntable speed allows the cleaning liquid to stay on the record so that the liquid has its appropriate affect and is not pressed outward by the centrifugal force The brush roller should at most lightly touch the record The cleaning effect results through the turbulent flow of the cleaning liquid under the brush After aprox 1 minute the plate changes its direction of rotation an iterative process...

Page 13: ...RUSH ARM For the normal wash sway the suction arm and also the round brush off the record and connect the hose that exit the device with the BRUSH ARM via the brush arm the cleaning liquid is applied Once the brush arm is situated adequately on the record you can fix the round brush with the rear on the round brush situated knurled screw It is recommended to wash the brush arm under flowing water ...

Page 14: ... small amount of wetting agents to avoid strong foaming Fill this agent into the supplied squeeze bottle and wet the record manually directly in front of the rotating brush roller while using the round brush 5 5 PUC WEIGHT The weight aligned to the center of the device serves to ensure that your record remains fixed and cannot stop The device has a ventilation hole located on the edge of the devic...

Page 15: ...e program LEFT and RIGHT with the SPEED BUTTON Until now in the old version you only have only the possibillity to chose the direction of the turntable and then go into the program LIQUID to drop cleaning fluid Set the output of the pump With the actual version you can set global the output of the pump For this choose the program LIQUID and turn the SPEED BUTTON To set the output higher turn the S...

Page 16: ...he speed of the turbine Reset the machien to default settings on the Mera ELB Eco 24V DC new version If you don t find your favorite settings or have a wrong setting and don t know how to set it back you can make a factory reset To do this step you need to turn off the machine into standby push 1x POWER BUTTON Push the SPEED BUTTON and hold it During holding the SPEED BUTTON press 1x short the POW...

Page 17: ... glass by opening the outlet 3 Make sure to close the outlet after the waste tank is void 4 Put the tube back under the machine where it was before Dispose the waste and never reuse it Also make sure not to incorporate this liquid Hannl Reinigungssysteme Beyenburgerstrasse 21 42899 Remscheid Telefon 492191 842 976 Telefax 492191 842 977 E Mail info vinylcare de ...

Page 18: ...with the rear thumb screw Optional mounting socket rotary brush extension set Already assembled with the ELB and B devices Do not replace the normal brush with the rotary brush The rotayry brush is not required for cleaning all discs Hannl Reinigungssysteme Beyenburgerstrasse 21 42899 Remscheid Telefon 492191 842 976 Telefax 492191 842 977 E Mail info vinylcare de ...

Page 19: ...ng fluid then you have set the brush too close to the disc Wet the disc by hand using the squeeze bottle supplied with the ELB and B models A small wave will form in front of the brush when you have applie sufficient cleaning agent To achieve optimal cleaning results change the direction in which the disc is rotated from time to time The time required for the operation depends on how dirty the dis...

Page 20: ... rotary brush please contact us on the following phone number during office hours 49 2191 842976 Outside office hour dial 0172 2038018 Mobile Phone We recommend using the rotary brush inconjunction with our specially developed non foamimg cleaning fluid VI3C You may also use our X 2000 dilutedone to one Cleaning performance will not be impaired and foam is not generated Hannl Reinigungssysteme Bey...

Page 21: ... brush release the two scews as illustrated You can then remove the brush Please note there is a spring inside the cover The mounting socket which allows the rotary brush to be fitted as a third arm is slotted to permit the brush to be aligned correctly There is a rubber cover inside the socket which can be removed to access the Philips screw which holds the socket in place Hannl Reinigungssysteme...

Page 22: ...rocedure after each waste water drainage to ensure that no foam can form in the container We urgently recomment not to leave any waste liquids of other manufacture in the waste container This is due tot he possible formation of fungi blocking the drainage bore and pipe After drainage also rinse the container wellt o ensure no liquid remains contaning residues We furthermore recommend not to fill s...

Page 23: ...C Directives In case of unauthorized changes this declaration will lose its validity Machine description vinyl record cleaning machine Ident no _________________________ Relevant EG Directives EC Machinery Directive 98 37 EC Low Voltage Directive 73 23 EEC EMV Directive 89 363 EEC Applied harmonised standards EN ISO 12100 1 2 EN 60204 EN 1050 EN 294 EN 349 Place Date __________________________ man...