background image

Limited Autom. 24V DC Vinyl cleaning machine

Information for the new features:

The Limited Autom. 24V DC have now a big 24V DC powerpack with 
integrated fan to take out the heat. 

The handling and the optic is the same quality.

If the main unit goes faulty you have only 24V DC on the front not longer 
110V/230V AC how on the old Limited autom. RB.

The CPU with the software can be updated in 1 minute by yourself without 
sending the machine. This have the advantage that you don't must resign on 
your machine and you can use your machine.
If you want to update you become a new CPU from us and send back the old 
one. A manual to change the CPU is included.

With the new 24V DC unit we have become the Limited Autom. 24V DC much
more quiet. 

The Limited Autom. 24V DC can bought in a based version without 
roundbrush for an cheap price. 
With extension sets how a roundbrush set or a extension main unit you can 
build your Limited Autom. 24V DC step by step up to an full Mera ELB Eco 
24V. 

A special system enables the customer to mounting the parts safety by 
thereself. If you have questions we are very glad to help.

Summary of Contents for Micro Autom

Page 1: ...Manual Hannl Reinigungssysteme Beyenburgerstrasse 21 42899 Remscheid Telefon 492191 842 976 Telefax 492191 842 977 E Mail info vinylcare de...

Page 2: ...that you understood everything before installing and using the device This manual will provide you with technical guidance that ensures cleaning and care of your records trouble free use of your devic...

Page 3: ...n to scrub a plate with a double brush head or a round brush for a longer period of time Due to the reduced rotation speed the detergent stays on the plate and won t be pushed off the plate by centrif...

Page 4: ...e plate off softly and gently In the PLATEPosition you ve got the option to scrub a plate with a double brush head or a round brush for a longer period of time Due to the reduced rotation speed the de...

Page 5: ...advantage that you don t must resign on your machine and you can use your machine If you want to update you become a new CPU from us and send back the old one A manual to change the CPU is included Wi...

Page 6: ...he direction of the plate in vacuum You can use this feature if you push the pump button in program VACUUM In the program VACUUM the machine changes the direction of the plate after 1 rounds In the pr...

Page 7: ...nd 5 Top view incl brushes and suction arm 5 1Suction arm 5 2 Double brush arm 5 3 Round brush 5 4 Tank 5 5 Weight 5 6 Turntable 6 Emptying used up cleaning liquid 7 Round brush 7 1 Installation of ro...

Page 8: ...ginal washing liquid may be used when cleaning the records 9 If the unit emits an abnormal odor or smoke turn it off immediately and disconnect the power cable 10 You must not wear loose garments that...

Page 9: ...RB 1 microfibre cloth Tool for round brush Important note Please do not through away the original packaging You will need it to protect your cleaning maching from possible damages during transportati...

Page 10: ...the cleaning procedure set the PROGRAMME SELECTION SWITCH to the STOP Position After having used your device the installed fan might conduct damp air away up to 10 minutes Then aprox 10 minutes later...

Page 11: ...anually and apply the cleaning liquid via the brush you will have to choose between LEFT and RIGHT and then switch to LIQUID 4 5 VACUUM With the function VACUUM the suction equipment will be activated...

Page 12: ...turntable speed allows the cleaning liquid to stay on the record so that the liquid has its appropriate affect and is not pressed outward by the centrifugal force The brush roller should at most light...

Page 13: ...USH ARM For the normal wash sway the suction arm and also the round brush off the record and connect the hose that exit the device with the BRUSH ARM via the brush arm the cleaning liquid is applied O...

Page 14: ...small amount of wetting agents to avoid strong foaming Fill this agent into the supplied squeeze bottle and wet the record manually directly in front of the rotating brush roller while using the round...

Page 15: ...program LEFT and RIGHT with the SPEED BUTTON Until now in the old version you only have only the possibillity to chose the direction of the turntable and then go into the program LIQUID to drop clean...

Page 16: ...e speed of the turbine Reset the machien to default settings on the Mera ELB Eco 24V DC new version If you don t find your favorite settings or have a wrong setting and don t know how to set it back y...

Page 17: ...glass by opening the outlet 3 Make sure to close the outlet after the waste tank is void 4 Put the tube back under the machine where it was before Dispose the waste and never reuse it Also make sure n...

Page 18: ...ith the rear thumb screw Optional mounting socket rotary brush extension set Already assembled with the ELB and B devices Do not replace the normal brush with the rotary brush The rotayry brush is not...

Page 19: ...g fluid then you have set the brush too close to the disc Wet the disc by hand using the squeeze bottle supplied with the ELB and B models A small wave will form in front of the brush when you have ap...

Page 20: ...rotary brush please contact us on the following phone number during office hours 49 2191 842976 Outside office hour dial 0172 2038018 Mobile Phone We recommend using the rotary brush inconjunction wit...

Page 21: ...brush release the two scews as illustrated You can then remove the brush Please note there is a spring inside the cover The mounting socket which allows the rotary brush to be fitted as a third arm is...

Page 22: ...ocedure after each waste water drainage to ensure that no foam can form in the container We urgently recomment not to leave any waste liquids of other manufacture in the waste container This is due to...

Page 23: ...Directives In case of unauthorized changes this declaration will lose its validity Machine description vinyl record cleaning machine Ident no _________________________ Relevant EG Directives EC Machi...

Reviews: