4.
Lift off the tank door, place the tank in the holder and use the chain to hold the tank. Connect
the regulator as shown in Fig. 5. Screw the black handle clock-wise to tighten. Turn the handle
counterclock-wise to remove. The hose must point down. Open the control door and check that
the valve is turned all the way clockwise to the “OFF” position. Open the tank valve. Apply a
solution of soapy water to the tank-regulator connection and to the valve-hose connection to
check for leaks. If soap bubbles continue to form, the connection has a leak. If a leak is found,
close the tank valve and tighten all connections.
NEVER USE A FLAME TO CHECK FOR
LEAKS.
Figure
5
NATURAL GAS CONVERSION
Natural gas conversion must be performed only by natural gas provider or service company.
1.
Disconnect the gas hose from the gas valve. See Fig.
6
.
Figure
6