1.

 

Purpose of documentation 

This guide contains basic information regarding HANPLAST photovoltaic 
modules,  their  installation  and  safe  handling.  All  instructions  should  be 
read and understood before attempting installation. If there are any ques-
tions, please contact your dealer or HANPLAST for further information. 
This documentation refers to the PV-modules themselves and is not meant 
to be a complete installation manual for personnel not specifically trained 
to PV-modules. It serves as a general reference. 
 
Generally,  the  installer  must  conform  to  all  safety  precautions  in  this 
documentation,  as  well  as  the  applicable  national  codes  and  standards 
when installing HANPLAST PV-modules. Before installing a solar photo-
voltaic  system,  the  installer  should  become  familiar  with  the  mechanical 
and electrical requirements for photovoltaic systems. Keep this documen-
tation in a safe place for future reference. 

2.

 

System components 

(modules and mounting system; standard scope of delivery) 
 

 

HANPLAST photovoltaic modules (type designation  
SW Premium Plus),  IEC 61215ed. 2,  IEC 61730 and  UL 1703 certi-
fied  framed  glass/foil  laminates  with  crystalline  solar  cells,  perma-
nently attached junction box, and double insulated 4mm

2

 wires termi-

nated in touch safe specific PV DC-connectors.  

 

The mounting system does not form part of HANPLAST’s supply. 

 

The  modules  were  tested  by  being  screwed  through  the  mounting 
holes in the frame. 

 

Any  module  without  a  frame  (laminate)  shall  not  be  considered  to 
comply  with  the  requirements  of  UL  1703  unless  the  module  is 
mounted  with  hardware  that  has  been  tested  and  evaluated  with  the 
module under this standard or by a field inspection certifying that the 
installed module complies with the requirements of UL 1703. 

3.

 

General safety relevant aspects 

Do  not  attempt  to  disassemble  the  module,  and  do  not  remove  any 
attached nameplates or components. Doing so will void the warranty. 

 

 

The modules are qualified for application class A: Hazardous voltage 
(IEC 61730: higher than 50V DC; EN 61730: higher than 120V), haz-
ardous power applications (higher than 240W) where general contact 
access is anticipated. 

 

The  module  is  considered  to  be  in  compliance  with  UL  1703  only 
when  the  module  is  mounted  in  the  manner  specified in this  module 
documentation. 

 

Installing  solar  photovoltaic  systems  requires  specialized  skills  and 
knowledge. It should be performed only by qualified and specially in-
structed personnel.  The  installer  assumes  all  risk  of injury,  including 
risk of electric shock. 

 

Use  only  equipment,  connectors,  wiring  and  mounting  hardware 
specifically designed for use in a photovoltaic system. 

3.1.

 

Precautions for mechanical installation 

 

SW Premium Plus modules are designed for installation with specific 
photovoltaic mounting systems. Other use lies within the full respon-
sibility of the installer. 

 

The mounting system must be capable of securely fixing  

SW  Premium  Plus  modules  exposed  to  uplift  or  load  pressures  of 
more than 5’400 N/m

2

 

The  mounting  structure  and  hardware  must  be  made  of  durable, 
corrosion- and UV-resistant material. 

 

Observe  all  instructions  and  safety  precautions  included  with  the 
mounting system to be used with the module. 

 

If modules are installed on roofs (non-building-integrated modules or 
panels),  a  fireproof  underlay  is  needed.  If  modules  are  installed  in 
roofs, all applicable local, regional and national codes and regulations 
have to be observed. 

3.2.

 

Precautions for electrical installation 

 

Before any manipulation at an installed PV plant, switch it off first on 
AC-side after on DC-side of the inverter or the charge controller. 

 

When disconnecting wires connected to a photovoltaic module that is 
exposed to light, an electric arc may occur. Arcs can cause burns, start 
fires or otherwise create safety (up to lethal electric shock) problems.  

 

Check  for  remaining  voltage  before  starting,  and  observe  the  local 
safety relevant regulations for such working conditions. 

 

Under  normal  conditions,  a  photovoltaic  module  can  produce  more 
current and/or voltage than reported at standard test conditions.  

 

Contact with a DC voltage of 30 V or more is potentially hazardous. 
Exercise  caution  when  wiring  or  handling  modules  exposed  to  sun-
light. 

 

With  a  serial  interconnection  of  the  modules,  the  sum  of  the  open 
circuit  voltage  (Voc)  at  the  lowest  anticipated  temperature  must  not 
pass  over  the  maximum  system  voltage  indicated.  The  maximum 
number of modules in series is indicated on the module power label. 

 

Accordingly,  the  values  of  ISC  and  VOC  marked  on  this  module 
should be multiplied by a factor of 1,25 when determining component 
voltage  ratings,  conductor  current  ratings,  overcurrent  device  sizes, 
and size of controls connected to the PV output. In the USA, refer to 
Section 690-8 of the National Electrical Code (NEC) for an additional 
multiplying factor of 125 percent (80 percent de-rating) which may be 
applicable.  

 

Only connect modules with the same rated output current in series. If 
modules are connected in series, the total voltage is equal to the sum 
of  the  individual  module  voltages.  Put  maximum  series  overcurrent 
protective device, where required. 

 

Only  connect  modules  or  series  combinations  of  modules  with  the 
same voltage in parallel. If modules are connected in parallel, the total 
current is equal to the sum of individual module or series combination 
currents. 

 

Never  connect  modules  in  parallel  without  string  diodes  or  adequate 
devices to avoid reverse current from one string to the other. 

 

Always use the same type of module within a particular photovoltaic 
system. 

 

If the sum of short circuit currents of the parallel connected modules 
passes over the reverse current (indicated on module power label and 
in  the  module  data  sheet),  string  diodes  or  fuses  have  to  be  used  in 
each  string  of  modules  connected  in  parallel.  These  string  diodes  or 
fuses  have  to  be  qualified  for  the  maximum  expected  current  and 
voltage. 

 

Observe  the  instructions  and  safety  precautions  for  all  other  compo-
nents  used  in  the  system,  including  wiring  and  cables,  connectors, 
DC-breakers, inverters, etc.  

 

Use  appropriate  safety  equipment  (insulated  tools,  insulating  gloves, 
etc) approved for use on electrical installations. 

3.3.

 

General prescriptions for installation 

 

Do not apply paint or adhesive to the modules. 

 

Do  not  use  mirrors  or  other  hardware  to  artificially  concentrate 
sunlight on the module. 

 

When  installing  modules,  observe  all  applicable  local,  regional  and 
national  codes  and  regulations.  Obtain  a  building  and/or  electrical 
permit where required. 

 

Keep  children  well  away  from  the  system  while  transporting  and 
installing mechanical and electrical components. 