GB
Technical data
Minimum flow pressure with downstream resistance
0,5 bar
Max. operating pressure
10,0 bar
Recommended operating pressure
1,0 - 5,0 bar
Test pressure
16,0 bar
Max. hot water temperature
80° C
Temperature scale adjustible
20° - 80° C
Safety check
38° C
Hot water connection
LH
Cold water connection
RH
Nominal capacity for ½" 3 bar
32 l/min
Nominal capacity for ¾" 3 bar
44 l/min.
Minimum flow rate
5 l/min.
The water temperature at the hot water inlet should be at least 2° C higher then the desired hot water temperature.
The Hansgrohe ½" thermostatic mixer, code number 1337318 can be used in conjunction with hydraulic or
thermostatically controlled combination boilers providing there is a minimum of 1,5 bar pressure.
The Hansgrohe ¾" thermostatic mixer, code number 1337418 cannot be used with combinaton boilers.
Spare parts
1
Thermoelement ½"
92601
Thermoelement ¾"
92631
1.1
O-ring for ½"
92602
O-ring for ¾"
92632
1.2
O-ring for ½" and ¾"
92603
O-ring for ¾"
1.3
O-ring for ½"
92604
O-ring for ¾"
92634
2
N. R. valve for ½"
92605
N. R. valve for ¾"
92635
2.1
Filter for ½"
92606
Filter for ¾"
92636
3
Isolation valve for ½" and ¾"
92607
4
Extension for ½" 40 mm
92610
Extension for ¾" 40 mm
92640