Important! 

The  fitting  must  be  installed,  flushed  and 

tested after the valid norms.

1.  Flush through the supply pipes.

2.  Place the mixer including the sealing washer in position 

on the sink.

3.  Slip the plastic washer, the slide washer, the metall 

washer and collar over the hoses and threaded base 

and tighten the collar nut by hand. If there is not enough 

space, please use only the slide washer and the metal 

washer without the plastic washer.

4.  Tighten screws.

5.  Connect  the  supply  pipes  to  the  isolation  valves; 

cold right -  hot left.

6.  Connect the hose with hose nut, taper sleeve, disc and 

washer.

7.  Mount the hose weight - be careful by the max. drawn 

out, otherwise the hose could be crack.

After the assembly!

8.  Dismount the handspray and the filter.

9.  Flush through the hose.

10. Clean the filter.

11.  Mount the filter and the handspray

12.  Re-connect down, handscrew (1 Nm).

The hot and cold supplies must be of equal pressures.

Operation

The mixer is activated by lifting the lever handle.

Turning to the left   = warmer water,

turning to the right  = cooler water.

The handspray can be drawn approx. 50 cm out of the 

arm lining. The flow is changed from jet to needle spray 

by applying slight pressure to the membrane on top of 

the handspray. After shutting off the water flow, the mixer 

returns automatically to the bath function.

To retract the hose easily it is only possible when the swivel 

arm is in the middle position.

If the waterflow drops, clean the filter located between 

hose and handspray.

Technical Data

Operating pressure:  

max. 1 MPa

Recommended operating pressure: 

0.15 - 0.5 MPa

Test pressure: 

1.6 MPa

(1 MPa = 10 bar = 147 PSI)

Hot water temperature:  

max. 80° C

Recommended hot water temp.: 

65° C

Rate of flow aerator spray  

by 0.3 MPa: 

ca. 11 l/min

Rate of flow shower spray  

by 0.3 MPa: 

ca. 10 l/min

Test certificate: 

WRAS

Hot water limiter: order separatly

Back flow and vacuum breaker 

Hansgrohe single lever mixers can be used together with 

hydraulically and thermically controlled continuous flow 

heaters if the flow pressure is at least 0.15 MPa.

Maintenance non return valve

The non return valves must be checked regularly according 

to DIN EN 1717 in accordance with national or regional 

regulations (at least once a year).

Spare parts

 (see page 3)

handle 

35891800

1.1  screw cover 

94186000

flange 

96014800

nut 

94194000

locking screw for handle 

96059000

cartridge cpl. 

92730000

fixing set 

95049000

hose weight 

98551000

hose 1,25 m 

95048000

fixing set for hose connection 

96099000

handspray assy  

35893803

aerator cpl. M24x1 B 

13914000

non return valve 

95333000

non return valve 

95332000

connection hose 900 mm 

95313000

1�

2�

3�

4�

5�

6�

7�

8�

9�

10�

11�

12�

13�

1�

Reviews: