SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
Assemblyseepage31
English
Do not use silicone containing acetic acid!
Dimensions
(see page 36)
Symboldescription
Adjustment
(see page 35)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Flowdiagram
(see page 36)
Rate of flow Normal spray
Handspray flow rate
Operation
(see page 37)
Do not rotate the spout further than 360º or
damage to the hose will result.
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Spareparts
(see page 39)
XXX = Colors
000 = chrome plated
800 = stainless steel optic
Testcertificate
(see page 40)
Cleaning
(see page 38) and en-
closed brochure
If the waterflow drops, clean the filter
located between hose and handspray.
Maintenance
(see page 38)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
4
Summary of Contents for AXOR Citterio 39835000
Page 31: ...31 Montage 1 2a 1 2 24 x 15 ...
Page 32: ...32 Montage Nr 10476220 Armaturenfett Grease 4a 4b 3 1 2 2b 24 x 15 ...
Page 33: ...33 Montage 5 8 CLICK 6 7 SW 10 mm SW 19 mm 8 Nm 3 Nm 9 10 ...
Page 34: ...34 Montage 14 13 11 12 15 1 Nm 2 min ...
Page 36: ...36 Maße Maße Durchflussdiagramm 1 2 ...
Page 38: ...38 1 1 2 2 ...