background image

4

English

Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 

and body cleaning purposes.

 

Children as well as adults with physical, mental and/

or sensoric impairments must not use this product 

without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from 

using this product.

 

The arm of the shower head is intended only to hold 

the shower head. Do not load it down with other 

objects!

 

Do not allow the streams of the shower touch sensitive 

body parts (such as your eyes). An adequate distance 

must be kept between the shower and you.

 

The product may not be used as a holding handle. A 

separate handle must be installed.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

• The installation dimensions stated in these installation 

instructions are ideal for people of approximately 

1700 mm in body height. The dimensions can be 

altered if required. In this case, pay attention to the 

fact that a change of installation height will also 

change the minimum height, and that the altered 

mounting dimensions must be taken into considera-

tion.

• During installation of the product by qualified trained 

personnel, make sure that the entire fastening surface 

is even and smooth (no protruding seams or tile 

offset), that the finish of the wall is suitable to apply 

the product and has no weak points.

• The mesh washer must be insert to protect the shower 

against incoming dirt by pipework. Incoming dirt 

leads to defects or/and can damage parts of the 

shower; such caused faults voids all liability and 

guarantee claims.

• The product is not designed to be used with steam 

baths!

• If required, the bottom part of the pipe between the 

fixture and the shower head can be shortened with a 

fine-toothed saw.

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,15 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 60°C 

Centre distance: 

150±12 mm 

Connections G 1/2: 

cold right - hot left 

Thermal disinfection: 

70°C / 4 min

• Safety against backflow

• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Adjustment 

(see page 10)

To adjust the hot water limiter. Using a hot water limiter in 

combination with a continuous flow water heater is not 

recommended.

Maintenance 

(see page 11)

The check valves must be checked regularly according to 

EN 806-5 in accordance with national or regional 

regulations (at least once a year).

Dimensions 

(see page 14)

Flow diagram 

(see page 15)

Spare parts 

(see page 20)

Special accessories 

(order as an extra)

• tile-matching-disk #95239000 

(see page 20)

Cleaning 

(see page 16)

Operation 

(see page 12)

To empty the overhead shower after use, hold it in a 

slightly inclined position.

Summary of Contents for Crometta S Showerpipe 240 1jet 26178007

Page 1: ...ZH 2 EN Instructions for use Assembly instructions 4 Crometta S Showerpipe 240 1jet 26178007...

Page 2: ...2 1700 mm 1 MPa 0 15 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 10 11 EN 806 5 14 15 20 95239000 20 16 12...

Page 3: ...3 6...

Page 4: ...be taken into considera tion During installation of the product by qualified trained personnel make sure that the entire fastening surface is even and smooth no protruding seams or tile offset that t...

Page 5: ...artridge defective calcified Exchange cartridge Mixer dripping Cartridge defective Exchange cartridge Hot water temperature too low Hot water limiter incorrectly set Set hot water limiter Instantaneou...

Page 6: ...6 1 2 X 36 mm X 36 X 1 2 36 mm max 39 mm max 5 mm SW 24 mm 1 2 3a 4 5 3b...

Page 7: ...7 A r m a t u r e n f e t t G r e a s e 2 1 Armaturenfett Grease 3 2 1 SW 30 mm 17 Nm 6 7 8 9 10 11...

Page 8: ...8 60 mm 6 mm 1 2 3 12 13 14 15 16...

Page 9: ...9 SW 3 mm 4 Nm 1 2 3 94246000 94246000 SW 17 mm 10 Nm 17 18 19...

Page 10: ...0 3 MPa 60 C 10 C 10 2 1 3 4 5 6 7 4 3 1 2 3 1 2 6 x 36 C 38 C 43 C 50 C 55 C 60 C 17 x S W 4 m m S W 4 m m 5 N m SW 4 mm SW 4 mm...

Page 11: ...11 1 2 3 4 SW 3 mm 1 2 3...

Page 12: ...12 1 1 3 2 2 2 1...

Page 13: ...13 1 2a 2b 2 1 1 Massage 2 IntenseRain 3 SoftRain Crometta Select S 26801407...

Page 14: ...14 240 15 15 max 100 12 54 22 60 G1 2 68 50 130 1 5 353 468 1025 210 G1 2 1900 1 0 0 50 42 44 62 150 12 289 800 1200 2000 min 2115 284...

Page 15: ...15 1 2 3 bar 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec...

Page 16: ...16 Hansgrohe Hansgrohe www hansgrohe int com guarantee QuickClean QuickClean QUICK CLEAN QUICK CLEAN...

Page 17: ...cts as the atomised spray could enter openings and gaps in the Hansgrohe products and cause damage After cleaning rinse thoroughly with clean water to remove any cleaner residue The use of steam clean...

Page 18: ...18 SW 17 mm 10 Nm SW 17 mm 1 min 1 2 3 4 5 6...

Page 19: ...19 1 min 94246000 1 2 3 4 5 6...

Page 20: ...67000 96157000 98137000 17x1 5 95140000 M4x20 92730000 97209000 M37x1 5 98154000 33x2 97406000 96338000 95620000 97738000 96466000 95404000 98913000 M34x1 5 96263000 95621000 96512000 M24x1 30 l min 9...

Reviews: