4
English
Assembly
(see page 33)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
•
31813000 / 31833000:
The mixer can not used
together with a continuous flow water heater.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 35)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Maintenance
(see page 37)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 38)
Flow diagram
(see page 39)
Spare parts
(see page 40)
Special accessories
(order as an extra)
Adapter (G⅜ / G½)
#93395000 (see page 40)
Cleaning
(see page 36)
Operation
(see page 42)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Test certificate
(see page 48)
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as
necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping in area of swivel
spout
- O-ring defective
- Exchange O-ring
Water escaping at the threaded
base
- connection hoses not completely
screwed into basic body
- Tighten connection hoses by hand
- O-ring at the connection hose
defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Summary of Contents for Decor 240 2jet 31815 3 Series
Page 33: ...33 3 Nm max 35 mm max 60 mm SW 10 mm SW 19 mm 4 Nm 110 110 150 150 1b 1a 2 3 4 5 ...
Page 34: ...34 1 2 2 min 1 CLICK 3 4 2 1 Nm 80 CLICK 8 9 10 11 6 7 ...
Page 37: ...37 1 1 2 2 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 47: ...47 ...