Installation Requirements
This thermostatic mixer valve must be installed in
compliance with current Water Regulations. If you have
any doubts about the Water Regulation requirements
contact your local water services provider or use the
services of a professional plumber.
This mixer valve is suitable for use with the following
water supply systems:
Gas Combination Boiler (multi-point) 1.0 - 10 bar*
Unvented System (pressure balanced) 1.0 - 10 bar
Pumped System 1.0 - 10 bar
IMPORTANT: If you install this mixer with a gravity
fed system, there must be a minimum head (vertical
distance) from the underside of tlie cold water storage
tank to the showerhead position of at least 5 metre.
Before connecting the mixer, water should be flushed
through the system to remove all debris that might
otherwise damage the valve.
* If pressure is in excess of 3.5 bar, a pressure-reducing
valve should be fitted.
KEY
Isolating valve
Reducing valve
Mixer Valve
Pump
Gas Combination Boiler (multi-point)