Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this shower
system without proper supervision. Persons under
the influence of alcohol or drugs are prohibited from
using this shower system.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The product is not designed to be used with steam
baths!
• The fitting must be installed, flushed and tested after
the valid norms!
• The plumbing codes applicable in the respective
countries must be oberserved.
ECOSTAT in conjunction with flow heat-
ers
• If fitting a hand shower remove the water limiter from
the shower.
• 13118000 / 13119000: In case of problems with the
continuous water heater or of greatly varying water
pressures, you must install the water limiter (comprised
in the delivery, article number 97510000) in the cold
water supply.
English
Maintenance
(see page 21)
• To guarantee the smooth running of the
thermostat, it is necessary from time to
time to turn the thermostat from total hot
to total cold.
• The mixer is equipped with check valves.
The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
Safety Function
(see page 18)
The desired maximum temperature for exam-
ple max. 42º C can be pre-set thanks to the
safety function.
Adjustment
(see page 17)
After the installation, the output tempera-
ture of the thermostat must be checked. A
correction is necessary if the temperature
measured at the output differs from the
temperature set on the thermostat.
Do not use silicone containing acetic acid!
Symbol description
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
4
Summary of Contents for Ecostat Comfort 13118000
Page 15: ...15 Ecostat Comfort 13118000 13119000 6 7 SW 30 mm 17 Nm 97510000 ...
Page 16: ...16 Ecostat Comfort 13279000 13286000 1 2 3 4 5 SW 2 5 mm SW 23 mm 17 Nm SW 2 5 mm 2 Nm ...
Page 17: ...17 1 4 2 3 ...
Page 18: ...18 z B 42 C for example 42 C 4 3 1 2 5 SW 3 mm 2 1 SW 3 mm 1 Nm ...
Page 22: ...22 SW 23 mm SW 6 mm 1 2 1 2 3 4 5 6 Ecostat Comfort 13279000 13286000 ...
Page 23: ...23 SW 6 mm 20 Nm 1 7 8 9 10 SW 23 mm 17 Nm 2 Ecostat Comfort 13279000 13286000 ...