Operation
(see page 19)
Dimensions
(see page 24)
Spare parts
(see page 26)
Test certificate
(see page 28)
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump
has been installed check to see if
the pump is working).
-
Filters are dirty (96922000 /
97367000 )
-
Clean filter in front of the mixer and
on the MTC-thermo cartridge
(96922000 / 97367000)
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
-
Backflow preventers dirty or leak-
ing
-
Clean backflow preventers, ex-
change if necessary
Spout temperature does not cor-
respond with temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to
42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Shower or spout dripping
-
Dirt or sedimentation on valve seat,
shut-off unit damaged
-
Clean or exchange shut-off unit
Instantaneous heater didn't work
with thermostat
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Filters are dirty
-
Clean the filter / exchange filter
-
check valve hasn't moved back
-
Exchange check valves
Assembly see page 14
Flow diagram
(see page 25)
Shower
Bath tub
Cleaning
(see enclosed brochure)
English
5
Summary of Contents for Ecostat Comfort 13118000
Page 15: ...15 Ecostat Comfort 13118000 13119000 6 7 SW 30 mm 17 Nm 97510000 ...
Page 16: ...16 Ecostat Comfort 13279000 13286000 1 2 3 4 5 SW 2 5 mm SW 23 mm 17 Nm SW 2 5 mm 2 Nm ...
Page 17: ...17 1 4 2 3 ...
Page 18: ...18 z B 42 C for example 42 C 4 3 1 2 5 SW 3 mm 2 1 SW 3 mm 1 Nm ...
Page 22: ...22 SW 23 mm SW 6 mm 1 2 1 2 3 4 5 6 Ecostat Comfort 13279000 13286000 ...
Page 23: ...23 SW 6 mm 20 Nm 1 7 8 9 10 SW 23 mm 17 Nm 2 Ecostat Comfort 13279000 13286000 ...
Page 25: ...25 Ecostat Comfort 13118000 13286000 Ecostat Comfort 13119000 13279000 ...