background image

4

Assembly see page 31

Fault

Cause

Remedy

Insufficient water

 

-

Supply pressure inadequate

 

-

Check water pressure (If a pump has been installed 
check to see if the pump is working).

 

-

Regulator filter dirty

 

-

Clean filter in front of the mixer and on the MTC-
thermo cartridge

 

-

Shower filter seal dirty

 

-

Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water pipe, 
or vice versa, when mixer is closed

 

-

Backflow preventers dirty or leaking

 

-

Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with tempera-
ture set

 

-

Thermostat has not been adjusted

 

-

Adjust thermostat

 

-

Hot water temperature too low

 

-

Increase hot water temperature to 42 ºC to 65 ºC

Temperature regulation not possible

 

-

thermo cartridge calcified

 

-

Exchange thermo cartridge

Instantaneous heater didn't work with thermostat

 

-

Filters are dirty

 

-

Clean the filter / exchange filter

 

-

check valve hasn't moved back

 

-

Exchange check valves

 

-

Flow limiter in handshower isn’t removed

 

-

Remove flow limiter

Shower or spout dripping

 

-

Dirt or sedimentation on valve seat, shut-off unit dam-
aged

 

-

Clean or exchange shut-off unit

Cleaning 

(see page 34)

Spare parts 

(see page 36)

Flow diagram 

(see page 35)

  Shower outlet

  Tub outlet

Dimensions 

(see page 35)

Operation 

(see page 33)

Maintenance 

(see page 34)

• The mixer is equipped with check valves. The check valves must be 

checked regularly according to DIN EN 1717 in accordance with 
national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary 

from time to time to turn the thermostat from total hot to total cold.

Adjustment 

(see page 32)

After the installation, the output temperature of the thermostat must be 
checked. A correction is necessary if the temperature measured at the 
output differs from the temperature set on the thermostat.

Safety Function 

(see page 32)

The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.

Do not use silicone containing acetic acid!

Symbol description

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 
injuries.

 

The product may only be used for bathing, hygienic and body cleaning pur-
poses.

 

Children as well as adults with physical, mental and/or sensoric impairments 
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.

 

The hot and cold supplies must be of equal pressures. 

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the applica-

ble standards.

• The plumbing codes applicable in the respective countries must be observed.
• The product is not designed to be used with steam baths! 

Thermostatic mixer in conjunction with combination boilers

• If fitting a hand shower remove the water limiter from the shower.
• If the continuous water heater causes any problems, or you have different 

water pressures you must install a water limiter to the cold supply, (ordered 
separately,article number 97510000). 

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,1 - 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

Centre distance: 

150 ±12mm

Connections G 1/2: 

cold right - hot left

• Safety against backflow
• The product is exclusively designed for drinking water! 

Special information for UK 

(see page 37)

English

Test certificate 

(see page 31)

Summary of Contents for Ecostat Comfort HQ 13112000

Page 1: ...n 9 PL Instrukcja obs ugi Instrukcja monta u 10 CS N vod k pou it Mont n n vod 11 SK N vod na pou itie Mont ny n vod 12 ZH 13 RU 14 HU Haszn lati tmutat Szerel si tmutat 15 FI K ytt ohje Asennusohje...

Page 2: ...hermos taten berpr ft werden Eine Korrektur ist erforderlich wenn die an der Entnahmestelle gemessene Temperatur von der am Thermostaten eingestellten Temperatur abweicht Safety Function siehe Seite 3...

Page 3: ...re de l eau puis e au miti geur thermostatique Un talonnage est n cessaire si la temp rature de l eau mitig e mesur e au point de puisage diff re sensiblement de celle affich e sur le thermostat Safet...

Page 4: ...correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat Safety Function see page 32 The desired maximum temperature for example max 42 C ca...

Page 5: ...dell acqua misurata sul punto di prelievo non corrisponde a quella fissata sul termostato Safety Function vedi pagg 32 Grazie alla funzione antiscottature Safety la temperatura massima per esempio max...

Page 6: ...na correcci n se efectuar siempre y cuando la temperatura del agua tomada a la salida del ca o no corresponda con la indicada en el volante del termostato Safety Function ver p gina 32 Gracias al tope...

Page 7: ...unction zie blz 32 Dankzijd de Safety Function kan de gewenste maximale temperatuur van bijv max 42 C van te voren worden ingesteld Gebruik geen zuurhoudende silicone Symboolbeschrijving Veiligheidsin...

Page 8: ...eratur afviger fra den p termostaten viste forindstilling er en korrigering af skalagrebet n dvendig Safety Function se s 32 Takket v re Safety varmtvands begr nsningen kan maksimaltempera turen forud...

Page 9: ...a medida no ponto de sa da diferir da temperatura marcada na escala Safety Function ver p gina 32 Gra as fun o de seguran a pode se regular a temperatura m xima por exemplo max 42 C N o utilizar silic...

Page 10: ...ciep wod Regulacja patrz strona 32 Po uko czeniu monta u nale y sprawdzi temperatur ciep ej wody na wylocie z termostatu Korekta b dzie konieczna wtedy gdy zmierzo na temperatura na wylocie r ni si od...

Page 11: ...e se mus zkontrolovat teplota vody vyt kaj c z termostatu Pokud se teplota zm en v m st odb ru li od teploty nastaven na termostatu je nutn prov st korekci Safety Function viz strana 32 D ky Safety Fu...

Page 12: ...termostatu Pokia sa teplota nameran na mieste odberu l i od teploty nastavenej na termostate je nutn vykona korekciu Safety Function vi strana 32 V aka Safety Function je mo n vopred nastavi najvy iu...

Page 13: ...13 31 42 C 65 C 34 36 35 35 33 34 DIN EN 1717 32 32 42 97510000 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 70 C 4 150 12mm G 1 2 31...

Page 14: ...14 31 42 65 34 36 35 35 33 34 DIN EN 1717 32 Safety Function 32 Safety Function 42 C 97510000 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65 C 70 C 4 150 12mm G 1 2 31...

Page 15: ...ani Beszerel s l sd a oldalon 32 A sikeres felszerel st k vet en ellen rizni kell a termoszt t kifoly si h m rs klet t Helyesb t s sz ks ges ha a v zkiv tel hely n m rt h m rs klet elt r a termoszt to...

Page 16: ...mostaatin ulostulol mp tila on tarkastettava S t on tarpeen jos k ytt pisteess mitattu veden l mp tila eroaa termostaattiin s detyst l mp tilasta Safety Function katso sivu 32 Safety Function ista joh...

Page 17: ...dan 32 N r monteringen r klar m ste termostatens t mningstemperatur kon trolleras En justering r n dv ndig om den uppm tta temperaturen vid tappningsst llet avviker fr n den som r inst lld p termostat...

Page 18: ...2 Sumontavus b tina patikrinti vandens i einan io i termostato tempe rat r Pakoreguokite vandens temperat r jei b tina Apsaugos funkcija r psl 32 Safety funkcija kar to vandens temperat ra gali b ti i...

Page 19: ...cu 32 Nakon instalacije treba ispitati izlaznu temperaturu termostata Ko rekcija je neophodna ako izmjerena temperatura na mjestu uzimanja odstupa od temperature koja je namje tena na termostatu Safet...

Page 20: ...s cakl k termostatta ayarlanan s cakl ktan farkl ysa bir d zeltme gereklidir Safety Function bak n z sayfa 32 Emniyet fonksiyonu sayesinde istenen maksimum s cakl k rn maks 42 C nceden ayarlanabilir...

Page 21: ...i temperatura de ie ire la termostat n cazul n care exist o diferen ntre temperatura m surat la golire i tempera tura reglat la termostat trebuie efectuat o corec ie Func ia de siguran vezi pag 32 Dat...

Page 22: ...22 31 42 C 65 C 34 36 35 35 33 34 DIN EN 1717 32 Safety Function 32 Safety Function 42 C 97510000 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 70 C 4 min 150 12mm G 31...

Page 23: ...izto no temperaturo na termo statu e na odvzemnem mestu izmerjena temperatura odstopa od temperature nastavljene na termostatu je potreben popravek Varnostna funkcija glejte stran 32 Varnostna funkci...

Page 24: ...lk 32 Paigaldamise j rel tuleb kontrollida termostaadi v ljundtemperatuuri Kui v ljavoolu kohas m detud temperatuur erineb termostaadiga sisestatust tuleb seda reguleerida Turvafunktsioon vt lk 32 T n...

Page 25: ...tekas viet at iras no termostat iestat t s temperat ras Dro bas funkcija skat lpp 32 Pateicoties dro bas funkcijai v lamo augst ko temperat ru piem maks 42 C var iestat t jau iepriek Neizmantot siliko...

Page 26: ...no hladnu vode Pode avanje vidi stranu 32 Nakon instalacije potrebno je ispitati izlaznu temperaturu termostata Korekcija je neophodna ako izmerena temperatura odstupa od temperature koja je name tena...

Page 27: ...ratur kontrolleres Det er n dvendig med korrektur n r temperaturen m lt ved uttaksstedet avviker fra temperaturen som er innstilt p termostaten Safety Function se side 32 Takket v re egenskapen Safety...

Page 28: ...28 31 42 C 65 C 34 36 35 35 33 34 DIN EN 1717 32 SafetyFunction 32 Safety Function 42 C 97510000 1 0 1 0 5 1 6 1 10 bar 147 PSI 70 C 65 C 70 C 4 150 12mm G 1 2 31...

Page 29: ...shum t ftoht Justimi shih faqen 32 Pas montimit duhet kontrolluar temperatura n dalje e termostatit Korrigjimet jan t nevojshme n se temperatura e matur n pik n e rrjedhjes s ujit nuk sht e nj jt me...

Page 30: ...30 31 42 65 34 36 35 35 33 34 DIN EN 1717 32 32 42 97510000 1 0 5 0 1 1 6 PSI 147 10 1 70 C 65 C 4 70 C 12mm 150 G 31...

Page 31: ...CB P IX DVGW SVGW ACS NF WRAS KIWA ETA PA IX 19693 ICB CN0422 1377 X X X 1 43 20147 13113000 PA IX 19692 IB CN0422 1377 X X X 1 43 20148 13114000 PA IX 19693 ICB CN0422 1377 X X X X 1 43 20147 1311500...

Page 32: ...32 1 4a 4b 2 3 z B 42 C for example 42 C 4 3 1 2 5 2 1 SW 3mm 1 Nm 1 2 SW 3mm 6...

Page 33: ...da s cak cald toplo kuum karsts topla varm i ngroht Bedienung ffnen Schlie en Warm Kalt Reinigung 1 2 ffnen ouvert open aperto abierto open bne abrir otworzy otev t otvori nyit s avaaminen ppna atidar...

Page 34: ...aranti Kontakt PT Recomenda es de limpeza Garantia Contacto PL Zalecenie dotycz ce piel gnacji Gwarancja Kontakt CS Doporu en k ist n Z ruka Kontakt SK Odpor ania pre istenie Z ruka Kontakt ZH RU HU T...

Page 35: ...13114000 Ecostat Comfort Care 13115000 Ecostat Comfort HQ 13113000 Ecostat Comfort 13116000 Ecostat Comfort Care 13117000 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20...

Page 36: ...96922000 98129000 14x2 94149000 SW 17 mm 95836000 96737000 98282000 Ecostat Comfort 13116000 95841000 95836000 98426000 19x2 95842000 95838000 95837000 95842000 Ecostat Comfort Care 13117000 Ecostat C...

Page 37: ...This thermostatic valve will suit supplies of HIGH PRESSURE HP S HP T Operating pressure max 10 bar Recommended operating pressure 1 5 bar Test pressure 16 bar Hot water temperature max 80 C Recommend...

Page 38: ...ANT If you install this mixer with a gravity fed system there must be a minimum head vertical distance from the underside of tlie cold water storage tank to the showerhead position of at least 5 metre...

Page 39: ...hese periods necessitating service work then the next in service test should be carried out at 18 to 21 weeks after commissioning 4 The general principle to be observed after the first 2 or 3 in servi...

Page 40: ...To guarantee a smooth running of the thermostatic element it is necessary from time to time to turn the thermostat from total hot to total cold The thermostatic mixer valve should be checked annually...

Reviews: