4
Concealed installation
• The rotation symmetrical body is horizontal and
vertical usable. Only exception installing the
bath-shower mixer with integrated safety
combination. In this case only a verticaly installation
is possible. Install the iBox always above the
bath-tup. If parts of the iBox will broken, the water
can flow in there!
• The iBox is suitable for both bath and shower
applications. When using the bath-shower mixer /
thermostatic mixer with shut-off and diverter unit
outlet, the lower outlet must have priority. If you
need only one outlet, choose either the top or the
bottom outlet and connect it. Close the unused outlet
with a plug.
• The hot and cold supplies must be of equal
pressures.
• Install body with the hot water supply left and cold
water supply right.
• Depth of fitting: 80 mm to 108 mm.
• extension 25 mm
• Extension Set 22 mm (when wall is not deep
enough) see installation instructions Finish set
The basic set can depending on the building application
be mounted in different ways, Installation examples
please see page 39 - 40.
A
Direct wall installation.
B
Direct wall installation with 10 mm adjustable
mounting studs.
C
Installation on carrier system.
D
Installation on prefabricated house installation
panels or finished cells.
E
Brick wall installation.
F
Installation with fixation set
Installation examples with measurements and pipe
dimensions can be found starting on page 34.
The installation dimensions stated in these installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a
change of installation height will also change the
minimum height, and that the altered mounting
dimensions must be taken into consideration. The
consumption was measured in combination with the
appropriate fittings (thermostat/mixer/in-wall valve) to
reflect actual application in practice.
Installation tip
To install the supply pipes, fix the iBox with a pipe in a
vice.
Flush piping system
To complete the installation flush out both hot and cold
water supply.The arrows on the flush body show which
inlet is connected to which outlet pipe, e.g. cold water to
the upper outlet and hot water to the lower outlet.If only
one outlet is required, the flush body must be turned 90°
after the first flush.
iBox in combinaton with an Exafill
bath filler with overflow and
waste
(see page 42)
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
R¾
Connections:
cold right - hot left
Rate of flow by 0,3 MPa:
Shower mixer:
32 l/min
Thermostatic mixer:
36 l/min
Thermostatic mixer with shut off unit:
26 l/min
Thermostatic mixer with shut off and
diverter unit:
26 l/min
Thermostatic mixer HighFlow (Outlet 1 + 2):
58 l/min
iControl:
30 l/min
Bath-shower mixer:
31 l/min // 24 l/min
Bath-shower mixer with integrated
safety combination:
25 l/min // 24 l/min