Fault
Cause
Remedy
Insufficient water
-
Spray former calcified, dirty
-
Clean spray former, exchanging if
necessary
-
Filter at the isolation valves soils.
-
Clean the filter / exchange filter
Mixer stiff
-
Cartridge defective, calcified
-
Exchange cartridge
Mixer dripping constantly with water
heater switched off
-
Cartridge defective
-
Exchange cartridge
Water escaping in area of swivel
spout
-
O-ring defective
-
Exchange O-ring
Water escaping at the threaded base
-
O-ring at the connection hose de-
fective.
-
Exchange O-ring
Water escaping bels ow handle
-
Cartridge defective
-
Exchange cartridge
Water run out below the skin
-
The connection of the hanspray is
not tighten
-
Tighten the connection
-
Hose have a defect
-
Exchange the hose
SafetyNotes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
With water heaters of 5 liters the flow rate at the
mixer should not exceed 5 l/min. In this case the
flow rate must be reduced at the isolation valve.
InstallationInstructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
TechnicalData
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 -0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Rate of flow:
max. 5 l/min
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Do not use silicone containing acetic acid!
Cleaning
(see page 35)
Assemblyseepage32
Spareparts
(see page 36)
Dimensions
(see page 31)
Symboldescription
Operation
(see page 31)
• Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
• When the storage tank is being heated,
the spout will drip.
Maintenance
(see page 34)
• The check valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
• When changing the spray former, it is
imperative to use one made for this type
of mixer.
4
Testcertificate
(see page 34)