4
English
Assembly
(see page 33)
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
Special information for UK
If installing this product with a pump, please be aware that it has to have negative
head switching. This product will not function with a positive head pump.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 37)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
Maintenance
(see page 39)
The check valves must be checked regularly according to EN 806-5 in accordance
with national or regional regulations (at least once a year).
Dimensions
(see page 38)
Flow diagram
(see page 38)
Spare parts
(see page 40)
XXX = Colors
000 = Chrome Plated
340 = Brushed Black Chrome
670 = Matt Black
800 = Stainless Steel Optic
Special accessories
(order as an extra)
• extension #43333000 (see page 40)
• special tool #95910000 (see page 40)
• Adapter (G⅜ / G½) #93395000 (see page 40)
Cleaning
(see page 39)
Operation
(see page 37)
• Hansgrohe recommends not to use as drinking water the first half liter of water
drawn in the morning or after a prolonged period of non-use.
• Minor leaking may occur briefly at the spout when opening the fitting via the
lever.
• Use the lever to open the tap and set the desired temperature. The water flow
can be paused by pressing the Select button on the face side of the spout. When
the tap is not used for a longer period of time, f.e. when retiring at night or
leaving the house, it must be closed completely by means of the lever.
Test certificate
(see page 44)
Fault
Cause
Remedy
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Water escaping at the threaded base
- O-ring at the connection hose defective.
- Exchange O-ring
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Low flow with Select valve after valve replacement
- Improper Select valve installed
- Replace Select valve (#98463000)
Select button stiff
- Select button soiled
- Clean Select button and grease 98201000 O-ring
(see page 40)