To garantee a smooth running of the thermoelent, it
is necessary from time to time to turn the thermostat
from total hot to total cold.
Important!
Do not dismantle the thermoelement only replace it cpl.
Check the non return valves, clean, renew if necessary
and lubricate with special valve grease.
Reassemble in reverse order.
Adjust unit.
In the event of frost hazard and draining the pies, the
installation unit must be removed.
If the hot water and cold water connection are exchaned,
turn the installation unit 180° around.
Technical data
Minimum flow pressure with
downstream resistance
0,1 bar
Max. operating pressure
10,0 bar
Recommended operating pressure
1,0 - 5,0 bar
Test pressure
16,0 bar
Max. hot water temperature
80° C
Temperature scale adjustible
20° - 80° C
Safety check
38° C
Hot water connection
LH
Cold water connection
RH
Nominal capacity for ½" and ¾" by 3 bar 66 l/min
Adjustment function from min. flow rate 13 l/min
The water temperature at the hot water inlet should be
at least 2° C higher then the desired hot water
temperature.
The Hansgrohe ½" thermostatic mixer (code number
15373180) and ¾" (code number 15374180), can
be used in conjunction with hydraulic or thermostatically
controlled combination boilers providing there is a
minimum of 1,5 bar pressure and the combinaton boiler
prepare enough water for the downstream consumption.
Spare parts
1
Setting knop
36391XXX
2
Cover plate
95028XXX
3
Sleeve
96635XXX
4
Thermoelement
96633000
5
Non return valve
96644000
6
Seals
96636000
7
Seals
96364000
8
Extension 40 mm
92615000
XXX
= Colors
000 chrome plated
090 chrome plated/gold
810 satinox
880 satin chrome
English
Temperaturbegrenzung for example max. 42° C
for example 42° C
1
2
3
4
Adjustment (please see page 4)