4
English
Assembly
(see page 35)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The diverter (type HC) installed in the bath mixer is
designed as an anti-retraction device. For this reason,
the lower edge of the diverter must be at least 25 mm
above the highest possible dirty water level.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 37)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 42)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 40)
Flow diagram
(see page 41)
Spare parts
(see page 39)
Cleaning
(see page 43)
Operation
(see page 38)
Test certificate
(see page 42)
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Instantaneous heater didn’t work
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
- Shower filter seal dirty
- Clean filter seal between shower
and hose
- check valve hasn't moved back
- Exchange check valves
Summary of Contents for Novus Loop 71340000
Page 14: ...14 35 HC 25 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 70 C 4 37 42 EN 806 5 40 41 39 43 38 42...
Page 26: ...26 35 HC 25 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 70 C 4 37 42 EN 806 5 40 41 39 43 38 42...
Page 28: ...28 35 HC 25 1 0 1 0 5 1 6 1 10 147 PSI 60 C 70 C 4 37 42 EN 806 5 40 41 39 43 38 42...
Page 29: ...29 35 HC 25 1 0 5 0 1 1 6 PSI 147 10 1 60 C 4 70 C 37 42 5 EN 806 40 41 39 43 38 42...
Page 35: ...35 SW 24 mm 36 mm X 36 mm X 36 X 5 1 3b 2 4 3a 1 2 1 2 max 39 mm max 5 mm...
Page 36: ...36 6 7 SW 30 mm 17 Nm SW 22 mm 2 min 8 9 10 11 SW 22 mm 2 Nm...