52
English
Failure
After a certain time of
showering the temperature
changes
Outlet temperature does not
correspond with the ad-
justed temperature
Error display
11.1C, 21.1C, 31.1C
(Motor alignment impossi-
ble)
Error display
1F, 2F, 3F, 4F
Error display
5F, 6F
Error display
8F
Error display
9F, 10F
Error display
11F
Possible Cause
Not enough stored hot
water
Temperature of the feed
hot water is too low
No motor alignment was
performed
Hot - and cold water supply
hoses are wrong way
around
Hot water heater is switched
off
Temperature and pressure
fluctuates
Error display is actuated by
built in test
Error display is actuated by
built in test
Light relay unplugged
Error display solenoids
Error display hot water
temperature over limit
Remedy
Increase hot water storage or temperature of the stored
water
Increase the temperature of the hot water cylinder
Perform motor alignment
Connect the supply hoses in the right way and perform
motor alignment
Switch on the hot water heater and wait until the tempera-
ture has reached 60 °C then perform motor alignment
Balance cold and hot water pressure (more than 1,5 bar),
cold water temperature between 4° C and 20° C, hot
water temperature should be more than 45° C, after
alteration perform motor alignment
Perform "Mains- reset", if error display is flashed further
on then actuate "Keyboard-reset" and perform motor
alignment, if no remedy possible contact technical service.
Actuate "Keyboard-reset" and perform motor alignment, if
no remedy is possible contact technical service.
Join light relay with control unit
Perform mains-reset, if no remedy is possible contact
technical service.
Actuate "Keyboard-reset" and perform motor alignment, if
no remedy is possible contact technical service.
T e c h n i c a l d a t a / a i d