4
Assembly see page 31
Fault
Cause
Remedy
Insufficient water
-
Supply pressure inadequate
-
Check water pressure (If a pump has been installed
check to see if the pump is working).
-
Filters are dirty (97973000)
-
Clean filter in front of the mixer and on the MTC-
thermo cartridge (97973000)
-
Shower filter seal dirty
-
Clean filter seal between shower and hose
Crossflow, hot water being forced into cold water
pipe, or vice versa, when mixer is closed
-
Backflow preventers dirty or leaking
-
Clean backflow preventers, exchange if necessary
Spout temperature does not correspond with
temperature set
-
Thermostat has not been adjusted
-
Adjust thermostat
-
Hot water temperature too low
-
Increase hot water temperature to 42 ºC to 65 ºC
Temperature regulation not possible
-
thermo cartridge calcified
-
Exchange thermo cartridge
Instantaneous heater didn't work with thermostat
-
Filters are dirty
-
Clean the filter / exchange filter
-
Non return valve hasn't moved back
-
Exchange non return valves
Test certificate
(see page 40)
Operation
(see page 36)
Cleaning
(see page 36)
Spare parts
(see page 40)
Flow diagram
(see page 37)
Dimensions
(see page 37)
Maintenance
(see page 38)
• To guarantee the smooth running of the thermostat, it is necessary
from time to time to turn the thermostat from total hot to total cold.
• The non return valves must be checked regularly according to DIN
EN 1717 in accordance with national or regional regulations (at
least once a year).
Safety Function
(see page 35)
The desired maximum temperature for example max. 42º C can be
pre-set thanks to the safety function.
Adjustment
(see page 34)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the
output differs from the temperature set on the thermostat.
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this shower system without proper supervision. Persons under the
influence of alcohol or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The shower system may only be used for bathing, hygienic and body cleansing
purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The fitting must be installed, flushed and tested after the valid norms.
• Where the contractor mounts the product, he should ensure that the entire area
of the wall to which the mounting plate is to be fitted, is flat (no projecting joints
or tiles sticking out), that the structure of the wall is suitable for the installation
of the product and has no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall constructions the manufacturer‘s
indications of the dowel manufacturer have to be taken into account.
• The filter insert must be use to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
Technical Data
Operating pressure:
max.1 MPa
Recommended operating pressure:
0,25 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
150 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
max. 70°C / 4 min
anti-pollution function
The product is exclusively designed for drinking water!
English
Summary of Contents for Raindance E Showerpipe 27149000
Page 34: ...34 24 26 3 mm 1 5 Nm 25 3 mm 1 5 Nm 23 1 3 2 4 mm 1 5 Nm 1 3 mm 1 5 Nm 2 3 mm 3 ...
Page 35: ...35 1 4 3 mm 1 5 Nm 7 3 mm 8 3 mm 3 mm 4 mm 3 mm 1 5 Nm 4 mm 1 5 Nm 3 mm 1 5 Nm 2 5 3 6 ...
Page 36: ...36 1 2 1 2 3 SW 5 mm 2 Nm SW 5 mm 1 2 90 1 2 3 90 1 2 3 ...
Page 37: ...37 ...
Page 39: ...39 ...