background image

Assembly see page 4

Fault

Cause

Remedy

Insufficient water

 

-

Supply pressure inadequate

 

-

Check water pressure (If a pump has been installed 
check to see if the pump is working).

 

-

Regulator filter dirty

 

-

Clean filter in front of the mixer and on the MTC-
thermo cartridge

 

-

Shower filter seal dirty

 

-

Clean filter seal between shower and hose

Crossflow, hot water being forced into cold water pipe, 
or vice versa, when mixer is closed

 

-

Backflow preventers dirty or leaking

 

-

Clean backflow preventers, exchange if necessary

Spout temperature does not correspond with tempera-
ture set

 

-

Thermostat has not been adjusted

 

-

Adjust thermostat

 

-

Hot water temperature too low

 

-

Increase hot water temperature to 42 ºC to 65 ºC

Temperature regulation not possible

 

-

thermo cartridge calcified

 

-

Exchange thermo cartridge

Instantaneous heater didn't work with thermostat

 

-

Filters are dirty

 

-

Clean the filter / exchange filter

 

-

check valve hasn't moved back

 

-

Exchange check valves

Spare parts 

(see page 16)

Cleaning 

(see page 13)

Operation 

(see page 12)

To empty the overhead shower after use, hold it in a slightly inclined 
position.

Flow diagram 

(see page 11)

  Hand shower

  overhead shower

Dimensions 

(see page 11)

Maintenance 

(see page 10)

• The mixer is equipped with check valves. The check valves must be 

checked regularly according to DIN EN 1717 in accordance with 
national or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it is necessary 

from time to time to turn the thermostat from total hot to total cold.

Adjustment 

(see page 8)

After the installation, the output temperature of the thermostat must be 
checked. A correction is necessary if the temperature measured at the 
output differs from the temperature set on the thermostat.

Safety Function 

(see page 9)

The desired maximum temperature for example max. 42º C can be pre-
set thanks to the safety function.

Do not use silicone containing acetic acid!

Symbol description

 

Safety Notes

 

Gloves should be worn during installation to prevent crushing and cutting 
injuries.

 

The arm of the shower head is intended only to hold the shower head. Do not 
load it down with other objects!

 

The product may only be used for bathing, hygienic and body cleaning pur-
poses.

 

Children as well as adults with physical, mental and/or sensoric impairments 
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.

 

Do not allow the streams of the shower touch sensitive body parts (such as your 
eyes). An adequate distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A separate handle must be 
installed.

 

The hot and cold supplies must be of equal pressures.

Installation Instructions

• Prior to installation, inspect the product for transport damages. After it has been 

installed, no transport or surface damage will be honoured.

• The pipes and the fixture must be installed, flushed and tested as per the applica-

ble standards.

• The plumbing codes applicable in the respective countries must be observed.
• The installation dimensions stated in these installation instructions are ideal for 

people of approximately 1800 mm in body height. The dimensions can be 
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting 
dimensions must be taken into consideration.

• During installation of the product by qualified trained personnel, make sure that 

the entire fastening surface is even and smooth (no protruding seams or tile 
offset), that the finish of the wall is suitable to apply the product and has no weak 
points.

• The mesh washer must be insert to protect the overhead shower against incoming 

dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the 
shower; such caused faults voids all liability and guarantee claims.

• For removal of the installed EcoSmart (flow limiter) from the shower, the pres-

sure must be lower than 0.2 MPa. With a pressure of more than 0.2 MPa, the 
EcoSmart must not be removed.

• The product is not designed to be used with steam baths!
• If the water connections are not stabil mounted, the fitting must be fixed with 2 

to 4 extra screws (see page 4, fig. A1 - A11). With this type of installation, take 
care not to puncture the water pipe! If the water connections are stabil mounted, 
no extra screws are required (see page 5, fig. B1 - B11).

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,3- 0,5 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

max. 70°C

Recommended hot water temp.: 

65°C

Thermal disinfection: 

max. 70°C / 4 min

Centre distance: 

150 ±12 mm

Connections G 1/2: 

cold right - hot left

The product is exclusively designed for drinking water!

English

Special accessories 

(order as an extra)

tile-matching-disk chrome plated #92143000 (see page 16)

Dismounting handle #98369000 

(see page 15)

3

Summary of Contents for Raindance Select E 360 Showerpipe EcoSmart 27287407

Page 1: ...ZH 2 EN Instructions for use assembly instructions 3 Raindance Select E 360 Showerpipe EcoSmart 27287407 40 C...

Page 2: ...16 13 12 11 11 10 DIN EN 1717 8 9 42 1800 mm 0 2 MPa 2 bar Ecosmart 0 2 MPa Ecosmart 2 4 4 A1 A11 5 B1 B11 1 MPa 0 3 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 70 C 65 C 70 C 4 150 12 mm G 1 2 92143000 16 9...

Page 3: ...flu ence of alcohol or drugs are prohibited from using this product Do not allow the streams of the shower touch sensitive body parts such as your eyes An adequate distance must be kept between the sh...

Page 4: ...1 2 SW 5 mm 4 Nm 40 C SW 3 mm 3 Nm 5 mm A5 A6 A8 A7 3 1 2 4 A9 2 1 A1 1 2 S i l i c o n e SW 5 mm 1 2 X X X 38 A2 1 2 5 mm X 38 mm 2x 4x A A10 A11 33 Nr 10476220 Armaturenfett G rease 1 2 A3 A4 SW 27...

Page 5: ...5 40 C B10 B9 B5 5 mm B6 B7 2 1 B1 1 2 S i l i c o n e SW 5 mm X X X 38 B2 1 2 5 mm X 38 mm B 40 C B11 33 SW 3 mm 3 Nm 1 2 B3 40 C B8 40 C SW 5 mm 4 Nm 1 2 B4 SW 27 mm...

Page 6: ...6 40 C 40 C 40 C 12 2 1 13 14 15 40 C 16 40 C 18 40 C 17 40 C 19 1 2 Nr 10476220 Armaturenfett G rease...

Page 7: ...7 40 C 40 C 1 2 3 20 4 1 2 SW 4 mm SW 17 mm 10 Nm 22 23 24 40 C Silicone 25 1 2 21 40 C 26 94246000 98058000...

Page 8: ...8 3 2 4 5 1...

Page 9: ...9 Safety Function 1 z B 42 C for example 42 C 2 3 2 1 5 6 7 8 4 Pr fzeichen...

Page 10: ...40 C Silicone 1 2 40 C 40 C 40 C 40 C 3 5 1 6 4 1 2 2 3 7 1 2 3 2 8 40 C 9 SW 22 mm SW 5 mm SW 22 mm 4 Nm SW 5 mm 4 Nm SW 3 mm SW 3 mm 3 Nm 1 1 2 3 10...

Page 11: ...5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 26 21 74 G 1 2 110 0 111 390 482 9 8 8 136 1 0 0 26 26 135...

Page 12: ...40 C open 40 C 40 C 40 C close hot cold 1 2 RainAIR Rain Whirl 1 2 12 1 2...

Page 13: ...ter openings and gaps in the Hansgrohe products and cause damage After cleaning rinse thoroughly with clean water to remove any cleaner residue The use of steam cleaners is not permitted The high temp...

Page 14: ...SW 5 mm SW 5 mm 2 Nm 25 mm SW 17 mm 1 3 5 2 4 6 1 min SW 17 mm 10 Nm 7 8 14...

Page 15: ...3 4 5 6 1 min 1 2 94246000 3x 3 4 5 6 3x 1 2 93339000 93339000 15...

Page 16: ...92142000 92295000 97735000 95416001 SW 5 mm 92144000 98371000 29x3 95773000 96429000 95772000 SW 27 mm 98199000 17x2 96179000 98058000 28276000 1 6 m 95758000 98140000 20x1 98367000 98282000 98370000...

Reviews: