Assembly see page 34
Cold water
Warm water
Installation example
(see page 38)
The wall must be reinforced in this area.
Center shower tub
(see page 38)
Flow diagram
(see page 38)
Dimensions
(see page 31)
Do not use silicone containing acetic acid!
Symbol description
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be observed.
Assembly
Install body with G 3/4 outlet pointing downwards. (see page 34)
Important! The gasket is not suitable for hot glue.
The iBox can depending on the building application be mounted in different ways,
Installation examples please see page 35.
1. Fig. 3a / 3A
Direct wall installation.
2. Fig. 3b / 3B
Direct wall installation with 10 mm adjustable mounting studs.
3. Fig. 3c / 3C
Installation on carrier system.
Bath tub / Exafill
(see page 42)
Tub outlet: Screw in the plug (Fig. 1 - 3)
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Rate of flow by 0,3 MPa:
Outlet 1 - 4:
26 l/min
Outlet Hand shower:
15 l/min
max. Rate of flow:
38 l/min
Connections G 3/4:
cold right - hot left
Connections overhead shower G 1/2
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Spare parts
(see page 44)
Cleaning
see enclosed brochure
4