background image

42

Safety and Important Information

Hansgrohe products are safe provided they are installed, used and maintained in 

accordance with these instructions and recommendations.
Please read these instructions thoroughly and retain for future use.
The plumbing installation of this thermostat mixing valve must comply with the 

requirements of UK.
Water Regulations/Bylaws (Scotland), Building Regulations or any other regulations 

specified by the local Water Authority and supplier.
The installation of thermostatic mixing valves must comply with the requirements of 

the Water Supply (Water Fittings) Regulations 1999.
We strongly recommend that you use a plumber registered with or a member of an 

Association:
Chartered Institute of Plumbing and Heating Engineering (CIPHE)
Water Industry Approved Plumber Scheme (WIAPS)
Dispose of plastic bags carefully.
Keep children well away from the work area.
Check for hidden pipes and cables in the wall before drilling holes.
The unit must be mounted on a finished waterproofed wall surface (usually tiles).
If you are using power tools (e.g. to drill holes) wear safety glasses and always 

disconnect tools from the power supply after use.
Do not operate the shower unit if the hand shower or spray hose has been dam-

aged or is blocked.
Do not block the flow of water from the hand shower, by placing it on your hand or 

any other part of your body or foreign object.
The thermostatic unit should be serviced annually by a qualified person to ensure 

maximum safety during use.
The thermostatic mixing valve will be installed in such a position that maintenance 

of the TMV and its valves and the commissioning and testing of the TMV can be 

undertaken.
The mixer is fitted with check valves (page 41 pos. 95773000). There are filters on 

the thermostatic element too (page 41 pos. 98282000).
The fitting of isolation valves is required (preferred location page 43 Installation 

Requirements).

Technical Hotline 

(for UK only)

Tel: 01372465655
Email: Technical@hansgrohe.co.uk
(Diese Servicehotline ist nur für das Vereinigte Königreich Großbritannien, nicht 

z. B. für Deutschland)

Technical Data

This thermostatic valve will suit supplies of:

HIGH PRESSURE (HP-S / HP-T)

Type 3 High Pressure shower HP-S only

Type 2 High Pressure shower or tub as appropriate HP-S and or HP-T

Operating pressure: 

max. 10 bar 

Recommended operating pressure: 

1 - 5 bar 

Test pressure: 

16 bar 

Hot water temperature: 

max. 60°C 

Recommended hot water temp.: 

55 - 60°C 

Rate of flow from bath spout: 

20 l/min. @ 3 bar

Rate of flow from shower outlet: 

18 l/min. @ 3 bar

Maximum outlet temperature: 

43°C +/-*

Safety check: 

40°C 

Hot water connection: 

Left hand 

Cold water connection: 

Right hand 

Mixed water temperature

Application 

Mixed water temperature

 

(at point of discharge).

Shower 

41°C max.

Washbasin 

41°C max.

Bath (44°C fill) 

44°C max.

Minimum difference between hot 

water and mixed water temperature: 

6 K

Hot and cold supply pressure should be balanced

* For preset outlet temperature adjustment – See page 35.

NB.

 If a water supply is fed by gravity then the supply pressure should be verified 

to ensure the conditions of use are appropriate for the valve.

Recommended outlet temperatures

The TMV scheme recommends the following set maximum mixed water outlet tem-

peratures for use in all premises:
44°C for bath fill but see notes below;

41°C for showers;

41°C for washbasins.

The maximum mixed water temperature can be 2°C above the recommended 

maximum set outlet temperatures.

Note:

 46°C is the maximum mixed water temperature from the bath tap. The maxi-

mum temperature takes account of the allowable temperature tolerances inherent in 

thermostatic mixing valves and temperature losses in metal baths.
It is not a safe bathing temperature for adults or children.
The British Burns Association recommends 37 to 37.5°C as a comfortable bathing 

temperature for children. In premises covered by the Care Standards Act 2000, the 

maximum mixed water outlet temperature is 43°C.

Installation Requirements

This thermostatic mixer valve must be installed in compliance with current Water 

Regulations. If you have any doubts about the Water Regulation requirements con-

tact your local water services provider or use the services of a professional plumber.
This mixer valve is suitable for use with the following water supply systems: 
Gas Combination Boiler (multi-point) 1.0 - 10 bar*

Unvented System (pressure balanced) 1.0 - 10 bar

Pumped System 1.0 - 10 bar

IMPORTANT:

 If you install this mixer with a gravity fed system, there must be a 

minimum head (vertical distance) from the underside of tlie cold water storage tank 

to the showerhead position of at least 5 metre.
Before connecting the mixer, water should be flushed through the system to remove 

all debris that might otherwise damage the valve.
* If pressure is in excess of 3.5 bar, a pressure-reducing valve should be fitted.

Supply Conditions TMV Type 2

Operating pressure range

High pressure

Maximum static pressure - bar

10

Flow pressure, hot and cold - bar

0.5 to 5

Hot supply temperature - °C

55 to 65

Cold supply temperature - °C

5 to 25

Valves operating outside these conditions cannot be guaranteed to operate as Type 

2 or Type 3 valves.

Commissioning and in-service tests

Commissioning
Purpose

Since the installed supply conditions are likely to be different from those applied 

in the laboratory tests it is appropriate, at commissioning, to carry out some simple 

checks and tests on each mixing valve to provide a performance reference point for 

future in-service tests.

Procedure

1. 

Check that:
a)  the designation of the thermostatic mixing valve matches the intended ap-

plication

b)  the supply pressures are within the range of operating pressures for the 

designation of the valve

c)  the supply temperatures are within the range permitted for the valve and by 

guidance information on the prevention of legionella etc.

2. 

Adjust the temperature of the mixed water in accordance with the manufac-

turer’s instructions (page 35) and the requirement of the application and then 

carry out the following sequence:
a)  record the temperature of the hot and cold water supplies

b)  record the temperature of the mixed water at the largest draw-off flow rate

On the following pages 42 - 43 

you can find important information 

only for the installation in UK

TMV

Summary of Contents for Showerpipe 260 1jet 24220 Series

Page 1: ...13 RU 14 FI K ytt ohje Asennusohje 15 SV Bruksanvisning Monteringsanvisning 16 LT Vartotojo instrukcija Montavimo instrukcijos 17 HR Upute za uporabu Uputstva za instalaciju 18 RO Manual de utilizare...

Page 2: ...50 12 mm Anschl sse G 1 2 kalt rechts warm links Thermische Desinfektion 70 C 4 min Eigensicher gegen R ckflie en Das Produkt ist ausschlie lich f r Trinkwasser konzipiert Symbolerkl rung Kein essigs...

Page 3: ...1 2 froide droite chaude gauche D sinfection thermique 70 C 4 min Avec dispositif anti retour Le produit est exclusivement con u pour de l eau potable Description du symbole Ne pas utiliser de silico...

Page 4: ...MPa Test pressure 1 6 MPa 1 MPa 10 bar 147 PSI Hot water temperature max 60 C Centre distance 150 12 mm Connections G 1 2 cold right hot left Thermal disinfection 70 C 4 min Safety against backflow Th...

Page 5: ...eratura dell acqua calda max 60 C Distanza di raccordo 150 12 mm Raccordi G 1 2 fredda a destra calda a sinistra Disinfezione termica 70 C 4 min Sicurezza antiriflusso Il prodotto concepito esclusivam...

Page 6: ...rvicio 0 1 0 5 MPa Presi n de prueba 1 6 MPa 1 MPa 10 bar 147 PSI Temperatura del agua caliente max 60 C Racores exc ntricos 150 12 mm Racores exc ntricos G 1 2 a la derecha frio a la izquierda calien...

Page 7: ...Aanbevolen werkdruk 0 1 0 5 MPa Getest bij 1 6 MPa 1 MPa 10 bar 147 PSI Temperatuur warm water max 60 C Aansluitmaten 150 12 mm Aansluitingen G 1 2 koud rechts warm links Thermische desinfectie 70 C 4...

Page 8: ...lutningsm l 150 12 mm Tilslutninger G 1 2 Koldt h jre varmt venstre Termisk desinfektion 70 C 4 min Med indbygget kontraventil Produktet er udelukkende beregnet til drikkevand Symbolbeskrivelse Der m...

Page 9: ...ress o testada 1 6 MPa 1 MPa 10 bar 147 PSI Temperatura da gua quente max 60 C Dist ncia entre eixos 150 12 mm Liga es G 1 2 fria direita quente esquerda Desinfec o t rmica 70 C 4 min Fun o anti retor...

Page 10: ...bezpieczony przed przep ywem zwrotnym Produkt przeznaczony wy cznie do wody pitnej Opis symbolu Nie stosowa silikon w zawieraj cych kwas octowy Safety Function patrz strona 36 Dzi ki funkcji zabezpiec...

Page 11: ...t n proti zp tn mu nas t V robky Hansgrohe jsou vhodn pro p m kontakt s pitnou vodou Popis symbol Nepou vat silikon s obsahem kyseliny octov Safety Function viz strana 36 D ky Safety Function je mo n...

Page 12: ...o Termick dezinfekcia 70 C 4 min Vlastn poistka proti sp tn mu nasatiu V robok je koncipovan v hradne pre pitn vodu Popis symbolov Nepou va silik n s obsahom kyseliny octovej Safety Function vi strana...

Page 13: ...13 34 1800 mm 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 36 42 C 35 40 EN 806 5 33 33 41 95239XXX 41 38 37 42 C 60 C...

Page 14: ...14 34 1800 Hansgrohe 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 150 12 G 1 2 70 C 4 Safety Function 36 Safety Function 42 C 35 40 EN 806 5 33 33 41 95239XXX 41 38 37 42 60 Select...

Page 15: ...sinfektio 70 C 4 min Est itsest n paluuvirtauksen Tuote on suunniteltu k ytett v ksi ainoastaan juomaveden kanssa Merkin kuvaus l k yt etikkahappopitoista silikonia Safety Function katso sivu 36 Safet...

Page 16: ...on 70 C 4 min Sj lvsp rr mot terfl de Produkten r enbart avsedd f r dricksvatten Symbolf rklaring Anv nd inte silikon som inneh ller ttiksyra Safety Function se sidan 36 Med hj lp av Safety Function k...

Page 17: ...in je kar tas kair je Terminis dezinfekavimas 70 C 4 min Su atbuliniu vo tuvu Produktas skirtas tik geriamajam vandeniui Simbolio apra ymas Nenaudokite silikono kurio sud tyje yra acto r g ties Apsaug...

Page 18: ...pis simbola Nemojte koristiti silikon koji sadr i octenu kiselinu Safety Funkcija pogledaj stranicu 36 Zahvaljuju u Safety funkciji mo e se podesiti eljena maksimalna temperatura npr i 42 C Regulacija...

Page 19: ...2 mm Racorduri G 1 2 rece dreapta cald st nga Dezinfec ie termic 70 C 4 min Asigurat contra scurgere napoi Produsul este destinat exclusiv pentru ap potabil Descrierea simbolurilor Nu utiliza i silico...

Page 20: ...0 34 1800 mm Hansgrohe 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 min Safety Function 36 Safety Function 42 C 35 40 EN 806 5 33 33 41 95239XXX 41 38 37 42 C 60 C Select...

Page 21: ...i na dezinfekcija 70 C 4 min Za ita proti povratnemu toku Proizvod je zasnovan izklju no za sanitarno vodo Opis simbola Ne smete uporabiti silikona ki vsebuje ocetno kislino Varnostna funkcija glejte...

Page 22: ...pp Toode on ette n htud eranditult joogivee jaoks S mbolite kirjeldus rge kasutage dikhapet sisaldavat silikooni Turvafunktsioon vt lk 36 T nu ohutusfunktsioonile on v imalik soovitud maksimaaltempera...

Page 23: ...temperat ra maks 60 C Piesl guma izm ri 150 12 mm G 1 2 piesl gumi aukstais pa labi karstais pa kreisi Termisk dezinfekcija 70 C 4 min Dro bas v rsts Izstr d jums ir paredz ts tikai dzeramajam denim...

Page 24: ...s simbola Nemojte koristiti silikon koji sadr i sir etnu kiselinu Safety funkcija vidi stranu 36 Zahvaljuju u Safety funkciji mo e se podesiti eljena maksimalna temperatura npr maks 42 C Pode avanje v...

Page 25: ...stre Termisk desinfisering 70 C 4 min Egensikker mot tilbakeflyt Produktet er utelukkende designet for drikkevann Symbolbeskrivelse Ikke bruk silikon som inneholder eddiksyre Safety Function se side 3...

Page 26: ...26 34 1800 Hansgrohe 1 0 1 0 5 1 6 1 10 bar 147 PSI 60 C 150 12 G 1 2 70 C 4 Safety Function 36 Safety Function 42 C 35 40 EN 806 5 33 33 41 95239XXX 41 38 37 42 C 60 C Select...

Page 27: ...0 1 MPa 1800 mm 1 MPa 0 1 0 5 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 150 12 mm G 1 2 70 C 4 Safety Function 36 Safety Function 42 C 35 40 EN 806 5 1 33 33 41 95239XXX 41 38 37 1 42 C 60 C Safety Stop S...

Page 28: ...projektuar ekskluzivisht p r uj t pijsh m P rshkrimi i simbolit Mos p rdorni silikon q n p rb rje ka acid acetik Funksionet e siguris shih faqen 36 Fal Safety Function mund t p rcaktohet temperatura...

Page 29: ...29 34 1800 1 0 5 0 1 1 6 PSI 147 10 1 60 C 12 150 2 G 1 C 07 4 36 42 35 40 5 EN 806 33 33 41 41 95239XXX 38 37 60 42 Select...

Page 30: ...i eren silikon kullanmay n Safety Function bak n z sayfa 36 Emniyet fonksiyonu sayesinde istenen maksimum s cakl k rn maks 42 C nceden ayarlanabilir Ayarlama bak n z sayfa 35 Montaj tamamland ktan so...

Page 31: ...3 tfoly si diagramm l sd a oldalon 33 Tartoz kok l sd a oldalon 41 Egy b tartoz k a sz ll t si egys g nem tartalmazza Csempekiegyenl t lemez Sz nk dol s 95239XXX l sd a oldalon 41 Tiszt t s l sd a old...

Page 32: ...32 34 1 80 MPa 1 MPa 0 5 0 1 MPa 1 6 MPa 10 bar 147 PSI 1 60 C 150 12 G 1 2 70 C 4 36 42 35 40 EN 806 5 33 33 41 41 95239XXX 38 37 MTC thermo 60 42...

Page 33: ...5 3 0 3 5 4 0 5 0 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 5 5 0 55 6 0 0 60 0 3 6 9 12 15 18 21 24 27 30 MPa 0 0 1 0 2 0 3 0 4 0 5 Q l min Q l sec 1 2 2 2 4 0 110 0 217 0 2 3 0 2 4 0 0...

Page 34: ...X 38 mm SW 3 mm 3 Nm 2 A r m a t u r e n f e t t G r e a s e 1 1 2 SW 4 mm 6 Nm 60 mm 2 3 1 6 mm A r m a tu r e n fe tt G r e a s e 37 38 m m SW 27 mm A r m a t u r e n f e t t G r e a s e 1 2 7 8 3...

Page 35: ...35 SW 3 mm 4 Nm 2 1 23 24 SW 2 mm 0 5 Nm 2 1 22 SW 2 mm 1 Armaturenfett Grease 2 21 18 16 3 1 2 20 19 15 14 17...

Page 36: ...36 SW 3 mm 1 2 for example 42 C z B 42 C SW 3 mm 1 Nm 1 4 7 11 2 5 8 3 6 9 10...

Page 37: ...l mmin varmt kar tas Vru a voda cald toplo kuum karsts topla varm i ngroht s cak meleg kalt froid cold freddo fr o koud koldt fria zimna studen studen kylm kallt altas Hladno rece mrzlo k lm auksts hl...

Page 38: ...r the spray nozzles to remove lime scale IT Facile da pulire Il calcare viene eliminato semplicemente dagli ugelli elastici in silicone ES F cil aseo La cal se puede retirar sencillamente frotando con...

Page 39: ...39 SW 2 mm 0 5 Nm SW 2 mm 2 2 1 1 1 min 40 mm 1 min max 10 min 3 5 4 2 1 2 6 1 3 4 5...

Page 40: ...m 1 2 2 SW 3 mm SW 3 mm SW 3 mm 3 Nm 1 2 SW 3 mm 4 Nm Rot Rouge Red Rosso Rojo Rood R d Vermelho Czerwony erven erven Punainen R d Raudona Crvena Ro u K Rde a Punane Sarkana Crvena R d Red E Kuqe K rm...

Page 41: ...0 72x2 92672000 94795000 98058000 98058000 94876XXX 95239000 Showerpipe 260 1jet 24220XXX Showerpipe 260 1jet EcoSmart 24221XXX 92340XXX 94880XXX Showerpipe 260 1jet EcoSmart 24221XXX 24111XXX 9565900...

Page 42: ...ressure should be verified to ensure the conditions of use are appropriate for the valve Recommended outlet temperatures The TMV scheme recommends the following set maximum mixed water outlet tem pera...

Page 43: ...wing procedure may be used 1 6 to 8 weeks after commissioning carry out the tests given in 2 on page 42 2 12 to 15 weeks after commissioning carry out the tests given in 2 on page 42 3 Depending on th...

Page 44: ...44 Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 01 2023 9 08422 01...

Reviews: