background image

2

English

 

Safety Notes

 

Gloves should be worn during installation to prevent 

crushing and cutting injuries.

 

The product may only be used for bathing, hygienic 

and body cleaning purposes.

 

Children as well as adults with physical, mental and/

or sensoric impairments must not use this product 

without proper supervision. Persons under the 

influence of alcohol or drugs are prohibited from 

using this product.

 

The hot and cold supplies must be of equal 

pressures.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 

surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be observed.

• If the thermostat or mixer is set to maximum water 

temperature, there is a risk of scalding at hydraulical 

opening of the check valve. For this reason, 

Hansgrohe recommends that you set up the "Safety 

Function".

Technical Data

Operating pressure: 

max. 1 MPa 

Recommended operating pressure: 

0,1 - 0,5 MPa 

Test pressure: 

1,6 MPa 

 

(1 MPa = 10 bar = 147 PSI) 

Hot water temperature: 

max. 60°C 

Thermal disinfection: 

70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking 

water!

Symbol description

Do not use silicone containing acetic acid!

Safety Function 

(see page 14)

The desired maximum temperature for example max. 

42º C can be pre-set thanks to the safety function.

Adjustment 

(see page 14)

After the installation, the output temperature of the 

thermostat must be checked. A correction is necessary if 

the temperature measured at the output differs from the 

temperature set on the thermostat.

Maintenance 

(see page 16)

• The check valves must be checked regularly 

according to EN 806-5 in accordance with national 

or regional regulations (at least once a year).

• To guarantee the smooth running of the thermostat, it 

is necessary from time to time to turn the thermostat 

from total hot to total cold.

Dimensions 

(see page 18)

Flow diagram 

(see page 18)

 

free flow

Spare parts 

(see page 20)

Special accessories 

(see page 20)

 

order as an extra

• extension 25 mm #13595000

• Extension Set 22 mm (when wall is not deep 

enough)#13597000, #13593000

• Bath Spout-Symbols #93577880

• levelling set 1° #95521000

Cleaning 

(see page 18)

Operation 

(see page 19)

+

Summary of Contents for ShowerSelect S 15743003

Page 1: ...EN Instructions for use Assembly instructions 2 DE Gebrauchsanleitung Montageanleitung 4 FI K ytt ohje Asennusohje 6 ShowerSelect 15763003 40 C ShowerSelect S 15743003 40 C...

Page 2: ...ed operating pressure 0 1 0 5 MPa Test pressure 1 6 MPa 1 MPa 10 bar 147 PSI Hot water temperature max 60 C Thermal disinfection 70 C 4 min Safety against backflow The product is exclusively designed...

Page 3: ...Increase hot water temperature to 42 C to 60 C Temperature regulation not possible thermo cartridge calcified Exchange thermo cartridge For new installations basic body incorrectly connected should b...

Page 4: ...triebsdruck 0 1 0 5 MPa Pr fdruck 1 6 MPa 1 MPa 10 bar 147 PSI Hei wassertemperatur max 60 C Thermische Desinfektion 70 C 4 min Eigensicher gegen R ckflie en Das Produkt ist ausschlie lich f r Trinkwa...

Page 5: ...tur Warmwassertemperatur erh hen auf 42 C bis 60 C Temperaturregelung nicht m glich Regeleinheit verkalkt Regeleinheit austauschen Bei Neuinstallation Grundk rper falsch angeschlossen Soll kalt recht...

Page 6: ...ne maks 1 MPa Suositeltu k ytt paine 0 1 0 5 MPa Koestuspaine 1 6 MPa 1 MPa 10 bar 147 PSI Kuuman veden l mp tila maks 60 C L mp desinfektio 70 C 4 min Est itsest n paluuvirtauksen Tuote on suunnitelt...

Page 7: ...C L mp tilan s t ei ole mahdollista l mp tilan s t yksikk kalkkeutu nut Vaihda l mp tilan s t yksikk Liitokset perusrunkoon on asennettaessa tehty v rin pit olla kylm oikealla l mmin vasemmalla tai p...

Page 8: ...8 SW 4 mm 90 90 SW 4 mm 5 Nm 4 SW 4 mm SW 5 mm 3 2 2 1 2 3 4 5 6 1 01850180 Armaturenfett Grease 1...

Page 9: ...9 SW 4 mm 7 8 9 10 1 2 0 mm 0 mm...

Page 10: ...10 1 2 SW 10 mm 2 Nm X X 11 1 2 mm 11 12 13 14 15 16...

Page 11: ...11 17 18 20 21 19 1 2 22 2 1 0 1 Nm SW 4 mm 90 90...

Page 12: ...12 1 2 1 2 max 5 24 25 26 23...

Page 13: ...13 SW 4 mm 90 90 0 SW 4 mm 5 Nm SW 4 mm 7 mm 2 SW 4 mm 90 90 C E D A B...

Page 14: ...14 z B 42 C for example 42 C 40 C 2 2 1 1 40 C 1 3 2 4 40 C 40 C 40 C 1 2 3 SW 3 mm...

Page 15: ...15 40 C 40 C 7 8 SW 3 mm 1 Nm 40 C 9 40 C 2 1 5 6...

Page 16: ...16 SW 4 mm 90 90 40 C 40 C 1 2 3 4 SW 4 mm 5 6 SW 27 mm 1 2 7...

Page 17: ...17 SW 4 mm 5 Nm 8 9 11 SW 27 mm 8 Nm 40 C 12 0 1 Nm 10 SW 4 mm 90 90 40 C 13...

Page 18: ...ect 15763003 www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com cleaning recommendation www hansgrohe com c...

Page 19: ...19 40 C 40 C 40 C 40 C 40 C 1 2 40 C open ffnen avaaminen close schlie en sulkeminen hot warm l mmin cold kalt kylm 40 C open ffnen avaaminen close schlie en sulkeminen 40 C...

Page 20: ...M5x20 SW 4 mm 98156000 36x2 94073000 95758000 98368000 M28x1 SW 19 mm 92219000 96454000 M5x55 98793000 145 mm 95843000 SW 3 mm 98197000 20x1 5 98282000 98146000 25x1 5 92146000 25x2 5 98913000 M34x1...

Reviews: