Operational States (continued)
Operational State
Description
Manual Mode
Manual mode allows the system to be operated manually.
This is a manual operation and should only be performed by a qualified technician.
Motor Fault Shutdown
A motor fault shutdown occurs when the system has experienced a critical fault related to the
operation of the pump motor.
This is an automatic operation which may require a system restart or evaluation by a qualified
technician.
Outlet Over-Pressure
When the system is set to maintain outlet flow and the outlet pressure rises above 35 psi. The system
will remain in this state until the outlet pressure drops below the 35-psi threshold.
Running Flush
A running flush occurs when the system has been continuously operating (continuous outlet flow) for
more than 30 to 60 minutes, depending on the inlet water TDS.
This is an automatic and relatively frequent operation which does not require any additional action.
Start-up Cycle
The start-up cycle is an automatic operation used during initial start-up only.
This is operation should only be performed by a qualified technician.
Sani-Cycle
The sani-cycle is a manual operation used only during full system sanitization.
This is a manual operation and should only be performed by a qualified technician.