background image

      

HANSA

Gas burner HMG

G

GB

F

ESP

Art.-Nr.:

1

Flammrohr

Flame tube

Tube de flamme

Tube de liama

1329

2

Stauscheibe

Baffle plats

Accroche flamme

Deflector con

1331

3

Gasdüse

2510

4

Doppel-Zündelektrode

Double ignition electrode

Electrode d´allumage

Deflector con

4174

5

Gehäuse

Box

2010

6

Luftmengenregler

Air regulator

1681

7

Gasdüsenstock kpl.

Gas combustion head compl. Ligne de gicleur gaz compléte Cabezal Mezclador de gas compl.

8

Gasfeuerungsautomat

Gas firing automat

Boîte relais gaz automatique Cofre de Seguridad para Q-gas unit

3089

9

Motor 230V/50Hz/70W

Engine 230V/50Hz/70W

Moteur 230V/50Hz/70W

Motor 230V/50Hz/70W

3434

10

Luftrad

Fanwheel

Ventilateur

Ventilador

1675

11

Zündtransformator

Ignition transformer

Transformateur d´allumage

Transformador de encendido

3174

12

Luftabschlußklappe

air choke

Volet d´air

Válvula de aire

1673

13

Pressungverstellschieber

Pressure slide lever 

Régulateur de pression

Regulador de aire

1674

14

Gas-Kompakteinheit

3722

15

Luftdruckwächter

3762

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Seite 1 von 5

Summary of Contents for HMG

Page 1: ...degascompl 8 Gasfeuerungsautomat Gasfiringautomat Boîterelaisgazautomatique CofredeSeguridadparaQ gasunit 3089 9 Motor 230V 50Hz 70W Engine230V 50Hz 70W Moteur230V 50Hz 70W Motor 230V 50Hz 70W 3434 10 Luftrad Fanwheel Ventilateur Ventilador 1675 11 Zündtransformator Ignitiontransformer Transformateur d allumage Transformadordeencendido 3174 12 Luftabschlußklappe air choke Voletd air Válvuladeaire ...

Page 2: ...second hand heat generators the heating surfaces have to be clean in order to achieve a good degree of effectiveness Gas pipes have to be laid professionally and must be absolutely impermeable Content of box 1 Gasburner HMG 2 Fixing screws M8 1Operating Manual mit 2 underlay discs 1 Flange gasket 1 Gasvalve 1 Plug with 7 poles 1 Conic case fixing screw Assembly First you take the burner out of its...

Page 3: ...3 7 3 6 3 6 3 5 3 4 3 3 3 2 3 1 3 0 2 9 2 8 32 0 27 5 35 6 4 2 4 1 4 0 3 9 3 8 3 7 3 6 3 5 3 4 3 3 3 2 3 1 36 0 31 8 40 0 4 8 4 6 4 5 4 4 4 3 4 2 4 1 3 9 3 8 3 7 3 6 3 5 40 0 34 4 44 4 5 3 5 2 5 0 4 9 4 8 4 6 4 5 4 4 4 3 4 1 4 0 3 9 45 0 38 7 50 0 6 0 5 8 5 7 5 5 5 4 5 2 5 1 4 9 4 8 4 6 4 5 4 3 50 0 43 0 55 6 6 6 6 5 6 3 6 1 6 0 5 8 5 6 5 5 5 3 5 1 5 0 4 8 Gasflowtable page 3 of 5 IMPORTANT Measur...

Page 4: ...Seite 4 von 5 Description and explanation of function of Dung s compact unit GB LEP 055D01 ...

Page 5: ...ththeaforementionedconditions faultyhandlingorwrongconnections theguaranteeexpires Electrical Connection Connecting of the 7 4 pole plug is done according to VDE 0116 and the electrical wiring diagram on page 5 Furthermore it is essential to take care of correct polarity of the Euro plugs connecting boiler and burner check of phasing If this instruction is not heeded this will automatically lead t...