9
Trouble shooting
message
meaning
action required
ICE
“
Ice
” – Potential freeze
condition detected.
No action required. The pumps and
the blower will automatically activate
regardless of spa status.
SnA
Spa is shut down.* The sensor
that is plugged into the Sensor
“
A
” jack is not working.
If the problem persists, contact your
dealer or service organization. (May
appear temporarily in an overheat
situation and disappear when the
heater cools.)
Snb
Spa is shut down.* The sensor
that is plugged into the Sensor
“
B
” jack is not working.
If the problem persists, contact your
dealer or service organization. (May
appear temporarily in an overheat
situation and disappear when the
heater cools.)
SnS
Sensors are out of balance.
If this is alternating with the
temperature, it may just be a
temporary condition. If the
display shows only this message
(periodically blinking), the spa is
shut down.
If the problem persists, contact your
dealer or service organization.
HFL
A substantial difference
between the temperature
sensors was detected. This
could indicate a flow problem.
Check water level in spa. Refill if
necessary. If the water level is okay,
make sure the pumps have been primed.
Press any button to reset.
LF
Persistent low flow problems.
(Displays on the fifth occurrence
of the “
HFL
” message within
24 hours.) Heater is shut
down, but other spa functions
continue to run normally.
Follow action required for “
HFL
”
message. Heating capacity of the spa will
not reset automatically; you may press
any button to reset.
dr
Inadequate water detected in
heater.
Check water level in spa. Refill if
necessary. If the water level is okay,
make sure the pumps have been primed.
Press any button to reset.
* On some systems even when spa is shut down, some equipment may occasionally turn on to
continue monitoring temperature or if freeze protection is needed.