7 SUPPLEMENTS
WARNING! Qualified technician required for service and installation
Basic installation and configuration guidelines
– Use minimum 6AWG copper conductors only.
– Torque field connections between 21 and 23 in lbs.
– Readily accessible disconnecting means to be provided at time of installation.
– Permanently connected.
– Connect only to a circuit protected by a class A ground fault circuit interrupter
(GFCI) or residual current device (RCD) mounted at least 5’ (1.52 m) from the inside
walls of the spa/hot tub and in line of sight from the equipment compartment.
– CSA enclosure: type 2
– Refer to wiring diagram inside the cover of the control enclosure.
– Refer to installation and safety instructions provided by the spa manufacturer.
Warning: People with infectious diseases should not use a spa or hot tub To avoid
injury, exercise care when entering or exiting the spa or hot tub Do not use a
spa or hot tub immediately following strenuous exercise Prolonged immersion
in a spa or hot tub may be injurious to your health Maintain water chemistry in
accordance with the Manufacturers instructions The equipment and controls
shall be located not less than 1 5 meters horizontally from the spa or hot tub
Warning! GFCI or RCD protection
The Owner should test and reset the GFCI or RCD on a regular basis to verify its
function.
Warning! Shock Hazard!
No User Serviceable Parts. Do not attempt service of this control system. Contact
your dealer or service organization for assistance. Follow all owner’s manual power
connection instructions. Installation must be performed by a licensed electrician and
all grounding connections must be properly installed.
CSA Compliance/Conformité
Caution!
– Test the ground fault circuit interrupter or residual current device before each use
of the spa.
– Read the instruction manual.
– Adequate drainage must be provided if the equipment is to be installed in a pit.
– For use only within an enclosure rated CSA enclosure 3.
– Connect only to a circuit protected by a class A ground fault circuit interrupter or
residual current device.