Setting up and aligning the
appliance
NOTICE
Risk of damage!
Insuffi cient air circulation may lead to
overheating and cause damage to the
appliance.
■
The entire space above the appliance
must remain clear.
■
The appliance should not stand di-
rectly against the wall (leave a mini-
mum clearance of 5 cm).
1. Place the appliance on as flat and as firm
a base as possible.
2. To ensure adequate air circulation,
– the entire space above the appliance
must be clear.
– the appliance should not stand directly
against the wall (leave a minimum clear-
ance of 5 cm)
– the clearance between the ventilation
slots and the wall, units or other appli-
ances must be at least 15 cm.
3. Check the position with a spirit level.
4. Level out any unevenness on the ground
using both of the front screw feet.
– Close the door.
– Tilt the appliance backwards slightly and
screw/unscrew the screw feet.
– Stand the appliance back up again and
check the alignment with a spirit level.
Repeat the process until the appliance
is standing up vertically. The appliance
should not move when opening the
doors.
Cleaning before use
In order to remove the odour which is present
in all new appliances, wipe the interior with
diluted vinegar prior to first use. Then wipe it
out with clean water and dry all of the parts
off afterwards.
Connecting the appliance to
electricity
WARNING
Risk of electric shock!
Touching live parts may result in severe
injury or death.
■
Do not operate or continue to oper-
ate the appliance if it
–
shows visible signs of damage, e.g.
the power cord is defective,
–
starts smoking or there is a smell of
burning,
–
makes unfamiliar noises.
In such cases, pull out the mains
plug or unscrew/isolate the fuse and
contact our service department (see
page EN-27).
■
Do not connect to a timer or a sepa-
rate remote-controlled system for dis-
tance monitoring and control.
■
If the mains plug is no longer acces-
sible after installation, an all-pole dis-
connecting device complying with
overvoltage category III must be
connected to the house wiring with a
contact gap of at least 3 mm; this in-
cludes fuses, circuit breakers and con-
tactors.
■
Do not kink or pinch the mains cord
or lay it over sharp edges. This can re-
sult in a break in the cable.
Start-up
Page EN-20