– If you would like to reduce these distances,
you can fit an insulation plate between the
appliances.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
an insulation plate made from solid mate-
rial.
Assembling the spacers
To ensure adequate air circulation, the appli-
ance must not lean directly against the wall.
(17)
• To maintain the correct distance to the
wall, screw the two supplied spacers (17)
into the threaded holes at the top on the
back of the appliance.
(17)
• Turn the spacers (17) by 90°, in order to
slot them into the fins.
Setting up and aligning the
appliance
NOTICE
Risk of damage!
Insuffi cient air circulation may lead to
overheating and cause damage to the
appliance.
■
The entire space above the appliance
must remain clear.
■
The appliance should not stand di-
rectly against the wall (leave a mini-
mum clearance of 5 cm).
1. Place the appliance on as flat and as firm
a base as possible.
2. Check the position with a spirit level.
(7)
3. Level out any unevenness on the ground
using the two front screw feet (7).
– Close the doors.
– Tilt the appliance backwards slightly and
screw/unscrew the screw feet (7).
– Stand the appliance back up again and
check the alignment with a spirit level.
Repeat the process until the appliance
is standing up vertically. The appliance
should not move when opening the
doors.
Start-up
Page GB-28
Summary of Contents for 4912 1660