A:
1898 mm
B:
833 mm
C:
300 mm
D: 652 mm
E:
1000 mm
F:
100 mm
G:
100 mm
H: 130°
I:
1400 mm
Minimum space requirement
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 1 m
3
per 8 g of refrigerant in compliance with
the EN 378 standard. A minimum space
requirement of 9 m
3
is necessary for your
appliance.
– The appliance must only be placed on a
level and firm surface. The surface must be
strong enough to support the appliance’s
weight when fully laden.
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
– The following minimum distances must be
maintained:
– to electric stoves
100 mm
– to oil and coal burning stoves 300 mm
– to other refrigeration appliances100 mm
– to washing machines/
dishwashers
100 mm
– If you would like to reduce the distance to
oil or coal-fired stoves, you can fit an insu-
lation plate between the appliances.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
an insulation plate made from solid mate-
rial.
Appliance dimensions and minimum distances
Start-up
Page EN-26