Page 14 of 16
SPA / SPB / SPAG series
Any kind of reproduction, even in parts, is not permitted.
Possible problems and solutions
Error
Cause
Solution
Lift table cannot be raised or
the desired lift height is not
reached
1) The valve (27) is dirty
2) Insufficient hydraulic oil
1) Clean valve no. (27)
2) Refill the hydraulic oil up to the lower
edge of the filler opening
The lift table can be raised,
but lowers itself again
1) The valve (27) is dirty
2) The pressure relief valve (20) is set
incorrectly
1) Clean the valve bore
2) Remove the valve (20) and clean it
or readjust it with a screwdriver
Lifting platform cannot be
lowered
(1) The wire cable is too long
2) The pressure relief valve is set
incorrectly
(1) Retension the wire cable by
loosening the nut on the L-piece (48)
and readjusting the screw
2) Remove the valve (20) and clean it
or readjust it with a screwdriver
Oil leaking at the pressure
relief valve
The O-ring seal (21) on the pressure
relief valve is defective
Replace the O-ring seal (21)
Table 1 Troubleshooting
Figure 13 Hydraulics
Summary of Contents for SPA Series
Page 197: ...4 16 SPA SPB SPAG 1 8 8 2 3 HanseLifter 4 5 HanseLifter...
Page 198: ...SPA SPB SPAG 5 16...
Page 199: ...6 16 SPA SPB SPAG...
Page 200: ...SPA SPB SPAG 7 16 180 HanseLifter...
Page 201: ...8 16 SPA SPB SPAG BGV D 27 39 HanseLifter...
Page 203: ...10 16 SPA SPB SPAG 2...
Page 205: ...12 16 SPA SPB SPAG SPA150 300 500 SPB500 3 4 SPA800 1000 1500 5 6 SPAG200 7 8...
Page 206: ...SPA SPB SPAG 13 16 9 10...
Page 207: ...14 16 SPA SPB SPAG SPA150 300 500 SPB500 SPAG 11 SPA800 1000 1500 12...
Page 208: ...SPA SPB SPAG 15 16 1 27 2 1 27 2 1 27 2 20 1 2 20 1 2 1 48 2 20 21 21 1 13...