background image

-

 18

 

Hanskamp AgroTech BV (The Netherlands)

 

www.hanskamp.com

 

L

port

 

EN

 

Sluithek 

-

 Closing gate 

-

 Schließbügel 

-

 Porte arrière automatique 

 

Assembly:

 

1.

 

Check that all the parts are present using the item list. The list of         

 

 

materials can be found in the appendix.

 

 

Please note! No fastening material is supplied to fit the L

port closing 

gate to the out of parlour feeder.

 

 

2.

 

Measure from the heart of the feeding trough ±1100 mm and from the 

 

heart of the anti

-

jump gate 575 mm high (fig. 3). Place at this measure 

 

the standing leg tube (art. no. 4109) at the side fences. Fastening        

 

 

materials are not included.

 

3.

 

Mount the tube assembly plate (art. no. 4106) and the two clamps 

 

(art. no. 1058) to both standing leg tubes (fig. 3A). Mount them loosely 

 

for further assembly but keep in mind to fasten them later!

 

4.

 

Place the 3

-

hole T

-

clamps (art. no. 4114) on top of the two standing leg 

 

tubes 

 

and connect the standing leg tubes with the cylinder assembly 

 

tube (art. no. 4110) (fig. 3B).

 

5.

 

Mount the double 4

-

hole half scale with cylinder assembly eyes (art. no.  

 

4103 & 4104) in the middle of the cylinder assembly tube (fig. 4).

 

 

 

Important! Make sure that the cylinder assembly tube is fixed well and 
cannot rotate in the 3

-

hole T

-

clamp. 

 

Make sure that the double 4

-

hole half scale cannot rotate on the        

cylinder assembly tube and is mounted correctly in the middle. The 

 

double 4

-

hole half scale should be in a position horizontal to the 

 

 

cylinder assembly tube. The L

port closing gate will operate incorrectly 

 

if these instructions are not followed. 

 

 

6.

 

Slide the hinge tube (art. no. 4108) in the tube of the moving element 

 

(art. no. 4111). Mount the hinge tube with the two tension pins (art. no. 

 

1555) to both sides (fig. 5a).

 

7.

 

Loosen the screw 1559 in the leg tube (fig. 5B). Add trough the nipple 

 

lubricant. This is for the prevention of noise and wearing out of the 

 

moving parts.

 

8.

 

Mount the hinge tube to the standing leg tube. Attach the hinge tube 

 

with the mounting clamps (fig. 3A). Make sure that the moving element 

 

is in the middle 

 

of the two 

 

standing leg 

 

tubes. Put the 

 

moving element 

 

on the available 

 

anti

-

jump gate.

 

      

 

 
 
 

Important! Make sure the horizontal tubes of 

the moving element are levelled when the 
moving element is mounted and rests on the 
anti

-

jump gate. Should this not be the case, 

 

adjust the height of the standing leg tubes 

 

again

.

 

3

 

   

 

± 1100 mm

 

3A

 

3B

 

4A

 

4

 

5A

 

5B

 

Summary of Contents for L'port

Page 1: ...n of original Instructions for use According to Appendix 1 Chapter 1 7 4 of the Directive 2006 42 EC on machinery Doetinchem The Netherlands www hanskamp com 004 000 000 Sluithek Closing Gate Schlie b...

Page 2: ...een compiled with care Hanskamp shall not be liable for errors or faults in this manual The recommendations are meant to serve as guide lines All instructions pictures and specifications in this manua...

Page 3: ...know that the feed goes to the right cow The L port closing gate is very simple to install with any type of out of parlour feeding station includ ing those with shorter side bars The L port closing ga...

Page 4: ...You must make sure that you and anyone else who operates the equipment performs maintenance on the L port or works in the vicinity of the L port are familiar with all the safety infor mation in this m...

Page 5: ...regulations Replace any damaged electrical cables cable sheaths switches and parts immediately Isolate or switch off the power supply before opening the L port and working on the electrical system 2...

Page 6: ...ir quality prescription Lubrication The cylinders have been designed for use with unlubricated air in which case no mainte nance is required If lubricated air is used lubrication must be continuous be...

Page 7: ...website www hanskamp com The order numbers and names of some parts are listed in the appendix Transport and storage The L port closing gate will be shipped on a pallet This pallet is completely seale...

Page 8: ...e foil on the back Place the sticker on the surface and press a small portion of the self adhesive layer onto the surface Carefully remove the foil and press down the rest of the sticker Remove any ai...

Page 9: ...nder assembly tube fig 4 Important Make sure that the cylinder assembly tube is fixed well and cannot rotate in the 3 hole T clamp Make sure that the double 4 hole half scale cannot rotate on the cyli...

Page 10: ...pling art no 1294 to loop the air supply fig 10 d in case of installing multiple L ports Recommended air pressure 6 bar The length of the supply tube is max 75 m Look at www hanskamp com for compresse...

Page 11: ...st the length of the cylinder rod to the fork fig 10 c so that it puts pressure on the anti jump gate in the lowest position 2 With the Speed in adjusting possibility that is indicated on the lid with...

Page 12: ...pressed air improperly in violation of the compressed air instructions drawn up by Hanskamp in collaboration with suppliers which causes a defect in the pneumatic systems These compressed air regulati...

Page 13: ...Connect new cable and remove the old one Gate goes right after the feedportion open again Waiting time is incorrect set Set Waiting time properly see page 11 Copyright and disclaimer The information...

Page 14: ...y that the following product L port 24VAC 24VDC type numbers 004 030 000 004 032 000 Universal closing gate to close off feed stations to which this declaration relates complies with the provisions of...

Page 15: ...universal fits on all types of out of parlour feeders 4032 L port closing gate XL extended back gate fits on DeLaval FSC40 0 FP200 Lely Cosmix S out of parlour feeders Dimensions Please note Dimension...

Page 16: ...el Porte arri re automatique Loose components It is possible to reorder loose components from your supplier for maintenance or for any other reason Please use the item numbers as shown on the drawings...

Page 17: ...17 18 Hanskamp AgroTech BV The Netherlands www hanskamp com L port EN Sluithek Closing gate Schlie b gel Porte arri re automatique...

Page 18: ...000 Nut M10 2 001 866 000 Nut self locking M10 8 004 045 000 4 hole half scale complete 1 004 106 000 Tube assembly plate 2 004 114 000 3 hole T clamp 1 x 1 2 004 115 000 Double T clamp 1 x 2 004 127...

Page 19: ...ds www hanskamp com L port EN Sluithek Closing gate Schlie b gel Porte arri re automatique Hanskamp AgroTech BV Broekstraat 17 7009 ZB Doetinchem The Netherlands Tel 31 0 314 393 797 Fax 31 0 314 393...

Reviews: