14.
Mount the rotor onto the shaft of the pump motor as illu-
strated in figure 13. Push the HanskampQualityTube in bet-
ween the rollers and the pump housing with a turning moti-
on. The HanskampQualityTube is now wedged between the
rollers and the pump housing.
Note: the tube must be as tightly packed as possible in
the curve of the pump housing (figure14).
15.
Take the transparent pump lid (art. no. 003
-
502
-
000) and
the 4 corresponding long flange head screws. Position the
lid so that it is immediately in front of the opening of the
pump housing. Tighten the screws evenly until the lid is
secure. Note: tight is tight! (figure 15).
16.
Connect the motor of the MultiDos HighSpeed to the corresponding control
system. Disconnect the feed station control board from the power supply before
connecting the motor cable.
Caution: Light electric chocks can occur when connecting the motor to the
control board.
Maintenance:
Check the MultiDos HighSpeed system daily for malfunctions and wear. Perform a visual
inspection of the supply and discharge hoses and electrical wiring. Periodically check
the dispensing quantity and calibrate if necessary. If the HanskampQualityTube is worn
out (leaky) due to intensive use, replace it according to the prescribed steps. An over-
hauling set is available from Hanskamp. Check the rollers and bearings for wear as well.
These are also available from Hanskamp if necessary.
Calibration:
Before calibration, manually control the motor until the liquid comes out of the
nozzle.
The MultiDos HighSpeed can be calibrated by having the feed computer send out a
pulse 10 times. Then measure the dispensed liquid and divide it by 10, enter this
value into the feed computer. Repeat this procedure once a month and after
changing liquid. Liquid concentrate is distributed simultaneously with normal con-
centrate over the entire active period of the day. Refer to your feed computer's
manual on how to use the feed curve. This is one of the calibration methods. If the
calibration method is described differently in your feed computer's manual, you
should apply that calibration method to the MultiDos HighSpeed.