Notifications & FAQ
12.1 Notifications
Program notifications
Possible cause
Solution
x hour not fed
Entrance of the feeding box blocked
Cows have been outside in the field for a long time
Antenna doesn
’
t recognize transponders (test with
a random transponder and check if transponder is
shown on the live monitor)
Remove blockage
If there is no recognition, try another Antenna
input, repair cable, or replace Antenna
Motor error (over current)
Dosator runs heavy/ is clogged
Motor runs heavy/ is broken
Connection error
Remove clogging
Replace Motor
Connect the Motor properly and/ or try another
exit on the PCB (see chapter 4.2)
Motor error (no feedback)
Motor has no feedback
Connection error
Motor takes to much time for rotation
Change Motor settings by
‘
Settings
’
-
>
‘
Custom
Motor Settings
’
Connect the Motor properly and/ or try another
exit on the PCB
Motor fault (short circuit)
Water damage or cable break
Motor defective
Replace motor or cable
Motor error (motor runs
continuously)
Electronics part in PCB defective
Continuous power on motor input
Switch motor to another output and configure
Backup failed
USB not placed correctly
Can not save backup
Remove USB and reinstall it
Restart Spider
PCB x not connected
This PCB is configured, but has no connection
Delete configuration
Fix PCB connection
Server reboots often
The SpiderServer has been restarted more than 3
times
Problem with power supply
Restarted several times due to e.g. an update