DPO6000, MPO6000 Series Digital Fluorescent Oscilloscope Product Manual V1.3
70
Threshold upper limit
1
2
n-1
n
Threshold lower limit
3. Rise Pulse Count: The number of rising edges rising from below the lower threshold
to above the upper threshold.
Threshold upper limit
Threshold upper limit
1
2
3
n
n-1
4. Fall Pulse Count: The number of falling edges from the upper threshold to the lower
threshold.
Threshold upper limit
Threshold lower limit
1
2
n-1
n
5. Trigger Count: The number of rising (or falling) edges from the threshold.
Threshold value
1
2
3
4
n-1
n
Note: The above measurement items are only applicable to analog channels. The de-
fault values for the upper and lower thresholds are 90% and 10%, respectively.