8060
HF Reject
ON/OFF
Reject high frequency signals
50%
Set the trigger level to the center of the signal
Pulse Trigger Setting
Pulse trigger occurs according to the width of pulse. The abnormal signals can be
detected through setting up the pulse width condition.
Press TRIG → F1 → Pulse button to show the pulse trigger menu as the following table.
The Pulse Trigger menu (Page 1/2)
Figure 2-27 The Pulse Trigger Menu
The Pulse Trigger menu (Page 2/2)
Figure 2-28 The Pulse Trigger Menu
The Pulse Trigger Table (Page 1/2)
Menu
Setting
Description
Source
CH1
CH2
Define CH1 or CH2 as trigger signal
When
+More
+Less
+Equal
-More
-Less
-Equal
+Pulse width more than selecting pulse condition
+Pulse width less than selecting pulse condtion
+Pulse width equal to selecting pulse condition
-Pulse width more than selecting pulse condition
-Pulse width less than selecting pulse condition
-Pulse width equal to selecting pulse condition
Setting
Value
Set required pulse width
1/2
Go to the next menu page