background image

Windows Software

EN

Copyright Qingdao Hantek Electronics Co., LTD

HTM200 user manual

45

Zoom

You can choose horizontal direction, vertical direction or both.
If you scroll the mouse wheel down to enlarge the line chart and up to shrink the line
chart.

Figure 8.11 Zoom

8.2.6 Shortcuts

Figure 8.12 Shortcuts

Screenshot

Take a screenshot of the line graph or bar graph and save it as a .png file to the
computer.

Run/stop

Run or stop button.

Move

After selecting the button, you can use the mouse up, down, left and right to move the
line chart. Click the button again to turn off this function.

Reset

Click this button to clear all collected temperature data and line charts.

Settings

You can set the temperature unit of the selected device or remove the selected device.

Interval

Set the interval for software to obtain the temperature.

Summary of Contents for HTM200 Series

Page 1: ...HTM200 Series Multi channel Temperature Recorder User Manual 2022 06...

Page 2: ...k Electronics Co LTD and requires products patents or works of a third party the company shall be responsible for obtaining the consent and authorization of the third party The above consent and autho...

Page 3: ...eral security issues 1 1 2 Safety Notices and Symbols 2 1 3 Measurement Category 3 1 4 Working Environment 3 1 5 Maintenance and Cleaning 5 1 6 Environmental Considerations 5 2 Product features 7 3 Do...

Page 4: ...troduction 14 4 3 7 Front Panel Overview 14 4 3 8 Side Panel Overview 16 4 3 9 Top Panel Overview 17 4 3 10 User Interface 17 4 4 Storage and replacement of batteries 19 4 4 1 Battery storage 19 4 4 2...

Page 5: ...1 Control via USB 30 6 2 Control via Bluetooth 31 6 3 Network data transmission 31 7 Android application 33 7 1 Application download and installation 33 7 2 Application introduction 34 7 2 1 Main inte...

Page 6: ...00 user manual Copyright Qingdao Hantek Electronics Co LTD IV 8 2 4 Record 44 8 2 5 Display 44 8 2 6 Shortcuts 45 8 2 7 Channel settings 46 9 Troubleshooting 47 10 Appendix 48 10 1 Appendix A Accessor...

Page 7: ...e 4 8 Open the stand 20 Figure 4 9 Install the battery 21 Figure 4 10 Safety lock hole 22 Figure 5 1 Measurement list 23 Figure 5 2 Measurement bar chart 24 Figure 5 3 Data preservation instance 28 Fi...

Page 8: ...38 Figure 8 1 Windows software user interface 40 Figure 8 2 File menu 40 Figure 8 3 Connection menu 41 Figure 8 4 Communication connection window 42 Figure 8 5 Windows software data collection 42 Fig...

Page 9: ...Table 4 1 Status display 19 Table 5 1 Channel configuration descriptions 25 Table 5 2 Function menu descriptions 25 Table 5 3 User menu table 26 Table 5 4 File menu table 27 Table 5 5 Function menu d...

Page 10: ...be connected to the ground before connecting the input or output end of the product Ensure that the product is properly grounded Check all terminal ratings To avoid fire or excessive current check all...

Page 11: ...ay from children Improperly replacing batteries can cause explosions warning lithium ion batteries Only the battery specified for the product shall be used Warning Equipment that meets class A require...

Page 12: ...instantaneous capacity of the device Measurement Class II refers to measurements made on circuits directly connected to low voltage equipment For example household appliances portable tools and simila...

Page 13: ...s the product Otherwise the operator may be in danger of suffering from electric shock Definitions of Installation overvoltage category Installation overvoltage category I refers to the signal level w...

Page 14: ...or placing the instrument Cleaning Check the instrument frequently as required by the operating conditions Clean the outer surface of the instrument according to the following steps 1 Use lint free cl...

Page 15: ...e of natural resources Some substances contained in the equipment may be harmful to the environment or human health if the product is not disposed of properly To avoid the release of harmful substance...

Page 16: ...limit or lower than the lower limit the buzzer will alarm Standard with type C communication function support optional Bluetooth module 4G communication module Equipped with Windows and Android data a...

Page 17: ...tons for example represents Utility button 2 Menu Use Menu text bold color blue to represent a menu option For example Serve represents clicking Serve on the current operation interface to enter the f...

Page 18: ...card 4G General 4G China HTM202E 2 Yes Yes Yes No Support HTM204B 4 Yes No No No No HTM204C 4 Yes Yes Yes No No HTM204D 4 Yes Yes Yes Support No HTM204E 4 Yes Yes Yes No Support HTM208B 8 Yes No No N...

Page 19: ...seriously damaged keep it until the machine and accessories pass the electrical and mechanical tests Check the accessories The details of the accessories are provided in Appendix A Accessories at the...

Page 20: ...ions Figure 4 1 Front view and side view 4 3 Preparation before Use 4 3 1 Adjusting the Stand When using the instrument the user can open the stand to tilt the instrument upward for easy operation and...

Page 21: ...ices 5V 500mA for charging through a Type C data cable Charging status description When charging in the case of battery installation the power indicator light is red and the battery box at the upper r...

Page 22: ...is product supports many languages you can click Language Edit to set the system language 4 3 5 Test terminal connection Figure 4 3 Test interface 1 represents connecting the positive end of the therm...

Page 23: ...the front and rear panels and the user interface of the device 4 3 7 Front Panel Overview Figure 4 4 Front panel 1 Display screen 2 8 inch TFT LCD screen 2 Menu buttons Corresponding to the four menus...

Page 24: ...limit or lower than the lower limit the buzzer will alarm ringing Press the button the backlight of the button will be on the alarm closing symbol will be displayed in the status bar and the alarm fun...

Page 25: ...light is green the temperature updates in real time Press the button and the backlight will turn red the temperature will stop updating 16 Measuring bar chart shortcut button In any interface press to...

Page 26: ...w Figure 4 6 Top panel 1 4G card slot Insert a 4G card Micro SIM card dimension 15mm 12mm Only for models with 4G module functions 2 SD card slot Insert a SD card FAT32 Only for models with SD card fu...

Page 27: ...Channel configuration Button lock symbol Press the backlight of the button will be on and the button lock symbol will be displayed in the status bar At this time only this button and power button are...

Page 28: ...USB Type C connection symbol will be displayed in the status bar Surplus electricity prompt Indicates the remaining electricity quantity If the battery box is red it indicates that the battery is low...

Page 29: ...specification of the battery is 18650 lithium battery 3 7V 2600mA Please refer to the following steps to replace 1 Open the standing you can see two screws Remove the screws and remove the battery co...

Page 30: ...be of the following sizes Heat shrink tube dimension thickness 0 2 0 3mm inner diameter 18 19mm length 21mm 2 Place it on the positive pole of the battery 3 Set the temperature of a heat gun to 270 th...

Page 31: ...e is reserved on the back cover of the instrument and the user needs to buy the safety lock by himself Wrap one end of the safety lock around a hard to move object Insert the other end into the safety...

Page 32: ...esults When the measured temperature is above the upper limit or below the lower limit the color of the temperature value on the List page will turn red The display page is shown as following Figure 5...

Page 33: ...ion page use arrow buttons to select the configurations that you want to modify Configurations descriptions Configuration item Descriptions Type The thermocouple types include J K T E S N B R A C D Th...

Page 34: ...tions Function menu Description Menu item Descriptions Edit Edit the parameter of the selected configuration item Reset Restore the parameter of the selected configuration item to its initial values F...

Page 35: ...een backlight time The screen will dim after the button is not operated for a specified period of time Automatic shutdown 5 min 10 min 30 min OFF Set the automatic shutdown time The instrument will sh...

Page 36: ...Function menu descriptions Menu item Descriptions Edit Edit the parameters of selected items Start Start saving data and automatically enter the List page Upload Hold down the soft button for 3 secon...

Page 37: ...el temperature The data format is float and one digit after the decimal point is reserved Channels are separated by Figure 5 3 Data preservation instance Note The instrument only saves temperature dat...

Page 38: ...r code description Error code Descriptions ERROR1 The temperature is out of the current thermocouple testable range Please refer to the Data Manual of this series for details of measuring ranges of di...

Page 39: ...product supports network data transmission Users can realize communication between the instrument and PC terminal or Android mobile terminal through 4G network module The instrument supports communic...

Page 40: ...his series 6 2 Control via Bluetooth Only the instrument with Bluetooth function supports Bluetooth data transmission For specific models see model list Press the power button to turn on the instrumen...

Page 41: ...led all buttons except the power button and the alarm button are disabled Press the return button and hold down for 3 seconds to turn off the network transmission function Note Before enabling 4G netw...

Page 42: ...the instrument s Android mobile application from Hantek s official website http hantek com cn products detail 12273 It can also be downloaded by scanning the QR code on the back of the instrument Figu...

Page 43: ...Home button 6 Unit 7 Pause Run button 8 page setting button A Gently point the channel on the screen and slide left and right and the channel will move with the finger B Gently point any position of...

Page 44: ...ave button to download the alarm upper limit alarm lower limit and thermocouple type to the instrument The channel names displayed by the application will also change Figure 7 3 Channel settings 7 2 2...

Page 45: ...on The application will obtain all the temperature data uploaded by the instrument on that day and the latest data in time D If offline simulation is selected as the data source the temperature displa...

Page 46: ...ved file and click OK to import the temperature data and display them on the line chart Figure 7 8 Data file import To delete the file tap the file name and hold for 2s Figure 7 9 Delete file Channel...

Page 47: ...8 Figure 7 10 Channel settings Line chart settings You can set the range of X and Y axes on a line chart The X axis is time and the Y axis is temperature Figure 7 11 Line chart settings Check the upda...

Page 48: ...the back of the instrument and download the software Application software installation Double click the Setup exe file and follow the installation wizard to install it After the installation is compl...

Page 49: ...ics Co LTD 40 8 2 Software Functions 8 2 1 User Interface Figure 8 1 Windows software user interface 1 Menu 2 Shortcuts 3 Temperature line chart 4 Switch button between line chart and bar chart 5 Temp...

Page 50: ...or bar chart screenshot as a png file 8 2 3 Connection Method Figure 8 3 Connection menu Connection modes include USB Bluetooth and network devices For details see Remote Control USB connection Connec...

Page 51: ...Windows software data collection Bluetooth connection Turn on the Bluetooth function of the temperature recorder and use a computer with Bluetooth function or a computer with Bluetooth adapter For th...

Page 52: ...Remote communication mode started the instrument will start uploading data Choose Connect Network Device input the SN and ID of the instrument and select Real time Data The software will obtain all t...

Page 53: ...directory of the software installation ON Select this menu to start recording and deselect to stop recording The file format is csv Each time you select this menu a new file will be generated 8 2 5 D...

Page 54: ...ot Take a screenshot of the line graph or bar graph and save it as a png file to the computer Run stop Run or stop button Move After selecting the button you can use the mouse up down left and right t...

Page 55: ...antek Electronics Co LTD 46 8 2 7 Channel settings Figure 8 13 Channel settings 1 Channel name You can click to edit the channel name 2 Channel switch 3 Temperature lower limit 4 Temperature upper lim...

Page 56: ...change the LCD brightness to the appropriate value 2 Check backlight time settings Press User then press to select the backlight time Press Edit to change the screen backlight time 3 The temperature...

Page 57: ...ronics Co LTD 48 10 Appendix 10 1 Appendix A Accessories This product provides the following accessories User can obtain all accessories from the local supplier Standard accessories Power adapter USB...

Page 58: ...g U Gu No 780 Baoyuan Road High tech Zone Qingdao Shandong Province Switchboard 400 036 7077 E mail service hantek com Tel 0532 55678770 55678772 55678773 Postcode 266000 Website www hantek com Qingda...

Reviews: