APPENDIX B: CLEARING NVRAM
To clear NVRAM on the Hantle 1700w™, begin by entering the Operator Function
Menu using the Master Password. Next enter the Customer Setup Menu.
Press the lowest button on the right side of the LCD panel. This will give you access
to the CLEAR NVRAM Menu.
*** WARNING ***
Once in the CLEAR NVRAM Menu, there is no extra authorization before data will be
wiped out permanently. DO NOT press any key within this menu unless you are
absolutely sure you want to permanently delete this data!
CLEAR JOURNAL
Selecting this will delete all journal data permanently
CLEAR NVRAM
This will delete all programmed parameters and return everything (including
passwords) to the default settings. This does NOT include the master keys which are
stored in the EPP.
CLEAR JOURNAL AND NVRAM
This option performs both of the options listed above. Both the programmed
parameters and journal are permanently deleted and all settings are returned to
default.