1.2.5 Main Control Board
Samsung S3C2440AL-40 RISC 32-bit CPU
64 MB RAM
WinCE™ 5.0 Operating System
Modem: 56,000 bps dial-up modem
TCP/IP Ethernet connection - Onboard SSL
Electronic Journal: 40,000 transactions
Battery back-up for set-up parameters (NVRAM)
Real time clock
1.2.6 Operating Environment
POWER REQUIREMENTS
110/220 VAC
r
10%, 50/60 Hz, 145 Watts
POWER CONNECTIONS
For warranty purposes, the Hantle C4000™ series ATM must be connected to a
dedicated power circuit. This circuit must consist of line, neutral, and ground leads
connected directly to the power circuit breaker panel. This circuit should not be
shared with any other equipment. Use of a surge protector or uninterruptible power
supply is recommended.
PHONE LINE REQUIREMENTS
The Hantle 4000 series ATM should be connected to a dedicated phone line. This line
must be a direct dial “tone” or “pulse” line that is equipped with a standard
telephone wall jack (RJ-11). This line cannot be shared with any other equipment at
the location. Use of shielded (CAT5) phone cable is recommended for best
performance and to reduce the chance of interference.
TEMPERATURE
In storage
: 32
q
F - 123
q
F (0
q
C
a
49
q
C)
While operating
: 40
q
F - 95
q
F (5
q
C
a
35
q
C)
HUMIDITY
In storage
: 10% < RH < 90%, non-condensed
While operating
: 15% < RH < 85%, non-condensed