12-24 V d.c 10 % (Ripple 10 % Max.)
50 mA Max.
Control : Open collector output, 100 mA
Stability :Open collector output, 100 mA
Remote / Reset input
0-1000
400 cps, Up/Down, 0~9999
12~9999 rpm
(Light On) / (Dark On) Output
NORMAL , ON DELAY, OFF DELAY, ONE Shot Time Output
1 ~ 9999 ms
Wavelength / 660 nm
Protection circuit from reversed power supply connection, Output short-circuit protection
1ms Max
10 % Max
LED 7, 4 digits FND
Auto-teaching, Manual
Adjustable bightness, 180 rotation display
Display time fixation, Zero reset, Initial reset, Lock function
Sunlignt : 10,000 lx Max., Incandescent lamp : 3,000 lx Max.
Operating : -10
~+ 55 , Storage : -25
~ +70
(Without freezing)
35 ~ 85 % R.H.
10-55 Hz(Cycle for 1 minute), Double amplitude : 1.5 mm, in each direction X Y Z for 2 hours
500
(50 G), X Y Z for 3 times
500 V a.c (50-60
for 1 minute)
Above 20 (500 V d.c)
DIN rail
cable 2 m, 5 P, 4
Bracket
MK0801E080108
Fiber Sensor Controller
PFD RM
We appreciate you for purchasing HanYoung NUX Co.,
Ltd product.Before using the product you have purchased,
check to make sure that it is exactly what you ordered.
Then, please use it following the instructions below.
1. To prevent defection or malfunction of this product, supply proper power voltage in
accordance with the rating.
2. Since this product is not designed with explosion-protective structure, do not use it at any
place with flammable or explosive gas.
3. Remove this product while the power is off. Otherwise, it may cause malfunction or
electric shock.
4. Due to the danger of electric shock, use this product installed onto a panel while an
electric current is applied.
Before you use, read safety precautions carefully, and use this product properly. The
precautions described in this manual contains important contents related with safety;
therefore, please follow the instructions accordingly. The precautions are composed of
DANGER, WARNING and CAUTION.
10 bit A/D 4Digit
Red LED
Multi-functions(MARK/RPM/COUNTER)
NPN Open collector
PNP pen collector
PFD
Light source
Use
External output
Multifunction: With built-in RPM/Count function, control output is possible
without a separate meter.
Safety information
WARNING
1. The contents of this manual may be changed without prior notification.
2. If you use the product with methods other than specified by the manufacturer, there may
be bodily injuries or property damages.
3. Avoid continuously switching the power source On and Off.
4. Use a dry cloth to wipe off the substance when cleaning the lens or cases. Never use
thinner or organic solvents.
5. Do not use this product at any place with much dust, vibration or impact.
6. Before inserting power source, make sure that the circuit wiring is properly connected.
7. In the case of wiring loaded inductors such as DC Relay and others to output, use diode,
varistor and others to prevent surge.
8. To avoid malfunction caused by noise, do not put high voltage or power line with sensor
wire in a same conduit
9. Make its wiring be shorter as possible and wire extension shall be within 30 m.
CAUTION
10. Consider the fact that the sensing distance may be varied in accordance with the size,
color, surface condition, material, glossy, non-glossy or others of a sensing object.
11. Prevent strong disturbance light such as sunlight and others which directly enter into the
directional angle of the sensor by putting a glare shield.
12. In the case of using multiple sensors (more than 2 sensors), there is a possibility of
malfunction caused by mutual interference so, for Through-Beam type, sensors shall be
installed in a divergent way or there shall be proper distance between them.
13. When using the Switching Power Supply as the power source, earth the Frame Ground
(F.G) terminal and be sure to connect the noise-eliminating condenser between 0 V and
F.G.
If you do not follow the contents described in the safety information then it is possible to be
a cause of the product’s malfunction so please follow them.
Frame
Power
Supply
(SMPS)
C(0.01
-0.1
/500 V)
- Noise Eliminating
Condenser -
Photo
sensor
NPN
PNP
Main
Subsidiary
COUNTER
RPM
Multi functions
PFD-RMN
PFD-RMP
Type
Kinds
Model
Rated Voltage
Current Consumption
Output
External Input
Mtensity of light
Multi
-functions
Output
On/Off Delay
Light source / Wavelenght
Protection Circuit
Response time
Varation rate
Display form
Sensitivity fixation
Additional functions
Operating Ambient illumination
Operating Ambirut temp.
Operating Ambient Humidity
Vibration Resistance
Shock Resistance
Dielectric Strength
Insulation Resistance
Connection Method
Accessory
Ordering information
Rating
Dimension
Multi-functions
Multi-functions
Counter
RPM
UP / DOWN mode, Free scale 1~999
Range: 0 ~ 9999 Counting speed: 400 cps (50 % duty )
Output mode : N, F, C, R, K, P, Q, A 8 kinds
External reset : Min. signal width 5 ms
Range : 0 ~ 9999 rpm Speed guard output
Free scale : 1 ~ 1000 Measring Cycle setting
Cautions) Use by combining the Fiber Unit in the form of transmission type at the time of
RPM/Count Measurement.
Malfunction can occur from the increase in the light receiving change range by speed
when using for the reflection purpose.
Distance measurement at the optical measurement mode changes in accordance with the
Fiber Cable and within 20m is recommended.